0xE8 user DALLAS/proximity card/key fob managing:

Read card/DALLAS list:

+ 4/8 bytes - user code (see example for 0xE0)
+ 1 byte

- '0' (ASCII 48 char)

Function result - 64 bytes:

1 byte

- 0xE8

1 byte

- '0'

31 bytes

- proximity card list

31 bytes

- DALLAS list

Read user proximity card:

+ 4/8 bytes - user code (see example for 0xE0)
+ 1 byte

- '1' (ASCII 49 char)

+ 1 byte

- user number (1..248) which proximity card to read

Function result - 8 bytes:

1 byte

- 0xE8

1 byte

- '1'

1 byte

- user number

5 bytes

- proximity card number

Write user proximity card:

+ 4/8 bytes - user code (see example for 0xE0)
+ 1 byte

- '2' (ASCII 50 char)

+ 1 byte

- user number (1..248) which proximity card to write

+ 5 bytes

- proximity card number

Read user DALLAS:

+ 4/8 bytes - user code (see example for 0xE0)
+ 1 byte

- '3' (ASCII 51 char)

+ 1 byte

- user number (1..248) which DALLAS to read

Function result - 9 bytes:

1 byte

- 0xE8

1 byte

- '3'

1 byte

- user number

6 bytes

- DALLAS number

Write user DALLAS:

+ 4/8 bytes - user code (see example for 0xE0)
+ 1 byte

- '4' (ASCII 52 char)

+ 1 byte

- user number (1..248) which DALLAS to write

+ 6 bytes

- DALLAS number

Read user INT-RX key fob:

+ 4/8 bytes - user code (see example for 0xE0)
+ 1 byte

- '7' (ASCII 55 char)

+ 1 byte

- user number (1..248) which INT-RX key fob to read

Function result - 14 bytes:

1 byte

- 0xE8

1 byte

- '7'

1 byte

- user number

4 bytes

- INT-RX key fob 28-bit serial number (high..low)

6 bytes

- settings of key presses (zones number to violate in INTEGRA panel)

1 byte

- bit list of keys that generate no events

Write user INT-RX key fob:

+ 4/8 bytes - user code (see example for 0xE0)
+ 1 byte

- '8' (ASCII 56 char)

+ 1 byte

- user number (1..248) which INT-RX key fob to write

+ 4 bytes

- INT-RX key fob 28-bit serial number (high..low)

+ 6 bytes

- settings of key presses (zones number to violate in INTEGRA panel)

+ 1 byte

- bit list of keys that generate no events

Read user ABAX key fob:

+ 4/8 bytes - user code (see example for 0xE0)
+ 1 byte

- '9' (ASCII 57 char)

+ 1 byte

- user number (1..248) which ABAX key fob to read

Function result - 14 bytes:

1 byte

- 0xE8

1 byte

- '9'

1 byte

- user number

3 bytes

- ABAX key fob 20-bit serial number (high..low)

6 bytes

- settings of key presses (zones number to violate in INTEGRA panel)

1 byte

- bit list of keys that generate no events

1 byte

- bit list (max. three '1's) of INTEGRA output status used as acknowledge

Write user ABAX key fob:

+ 4/8 bytes - user code (see example for 0xE0)
+ 1 byte

- 'A' (ASCII 41 char)

+ 1 byte

- user number (1..248) which ABAX key fob to write

+ 3 bytes

- ABAX key fob 20-bit serial number (high..low)

+ 6 bytes

- settings of key presses (zones number to violate in INTEGRA panel)

+ 1 byte

- bit list of keys that generate no events

+ 1 byte

- bit list (max. three '1's) of INTEGRA output status used as acknowledge