OPERATION

djustment keys: The USDT 3000 user interface is accessible

via the three

pushbuttons. The forward key (1) is used for scrolling forward through the indication

menu or to increase the adjustment values. The backwards key (2) is accordingly used for the
reverse function.

To enter the parameter adjustment mode hold the forward key for 2 sec while HO is displayed.
The “SEt” icon will be displayed on upper corner of LCD once
you are in the adjustment mode. Now, you can select the
parameter you wish to adjust by using the forward and
backwards keys. Press the key “SEt” (3) in order to change the
selected parameter:

Select a parameter by keys 1 and 2

Shortly press key 3, so that “SEt” flashes

Adjust the value by keys 1 and 2

Press key 3, so that “SEt” permanently appears, the adjusted value is now saved


Please note: The circulation pump (A1) stops at tank temperature of 90 °C to avoid tank
overheating.

Parameter List

TC

Collector temperature

TS

Tank (return) temperature

TT

Thermostat temperature (control temperature for R2 relay)

HO

Solar operating hours (to be used for energy calculation)

DO

Pump starting temperature difference

DF

Pump switch off temperature difference

SX

Maximum tank temperature

CL

Collector limiting temperature

CX

Maximum collector temperature

CN

Minimum collector temperature

TO

Thermostat (R2) switch on temperature

TF

Thermostat (R2) switch off temperature

FN

Function:

0 : Maximum tank temperature disable

1 : Maximum tank temperature enable

2 : Maximum tank temperature disable, cooling function enable

3 : Maximum tank temperature enable, cooling function enable

MM

Manual operation mode:

0 : relays R1 and R2 are deactivated

1 : relay R1 is activated, relay R2 is deactivated

2 : relay R1 is deactivated, relay R2 is activated

3 : relays R1 and R2 are activated

4 : automatic operation

PG

Program number

VN

Version number