POWER: This green LED lights when power is applied to the unit.

2

DTE T1 Status: This red LED lights a minimum of 0.1 second if the internal alarm circuitry detects any one of the following conditions
from the DTE: one or more BPVs, FBEs, CRCs, low ones density, or a loss of signal/loss of sync condition for Š 175 bit times from the
network. The LED stays lit until the unit detects Š 4 pulses in 32 bit times.

3

Network T1 Status: This red LED lights a minimum of 0.1 second if the internal alarm circuitry detects any of the following conditions
from the incoming T1 signal: one or more BPVs, FBEs, CRCs, or a loss of signal/loss of sync condition for Š 175 bit times from the net-
work. The LED stays lit until the unit detects Š 4 pulses in 32 bit times.

4

Loop: This amber LED lights under the following conditions: the manual loop switch is placed in the ‘LOOP’ position, the unit receives
an inband loop code for > 5 seconds, or the unit receives an FDL loop message (PLB or LLB). The LED does not light if the test switch is
placed in the ‘NORM’ position or if an inband or FDL unloop code is received for >5 seconds.

5

Test Switch: This 2-position switch is used for local testing. When placed in the local loop mode (LOOP), the unit loops the signal from
the customer equipment (DTE IN) back to the customer equipment (DTE OUT). It also loops the received signal from the T1 facility (NET
IN) back to the T1 facility (NET OUT). When moved back to ‘NORM’, the local loopback is removed.

T

R

A

N

S

P

O

R

T

®

210 CSU

Configuration Guide

Part Number 45-00042
Rev 1.00

LOOP

NORM

PWR

DTE

NET

LOOP

PRODUCTIVITY

SERIES

210

TxPORT 210 Front Panel

5

4

3

2

1

SPECIFICATIONS

Network Interface

Line Rate:

1.544 Mb/s (± 50 bps)

Line Framing:

Transparent

Line Code:

AMI or B8ZS

Line Impedance:

balanced 100

(± 5%)

Input Signal:

DS1, +1 to -30 dB (ALBO)

Output Signal:

3.0 V, ±15%, base-peak into 100 ¾

Line Build Out:

0, -7.5, -15, and -22.5 dB attenuation

Line Protection:

1000 V lightning, fused input/output

Jitter Control:

per TR62411 and T1.403

Pulse Density:

per TR62411

Equipment Interface

Line Rate:

1.544 Mb/s (± 50 bps)

Line Framing:

Transparent

Line Code:

AMI or B8ZS

Line Impedance:

balanced 100

(± 5%)

Input Signal:

DSX1 to 655 feet

Output Signal:

Selectable DSX1 signal level from 0 to 655 feet

Line Protection:

1000 V lightning, input/output

Mechanical

Mounting:

desktop or wall

Dimensions:

1.75" H, 6.8" W, 10.5" D

Weight:

2 lbs.

Industry Standards

FCC Compliance:

Part 15 Subpart B, Class A

FCC Part 68 Reg:

FXKUSA- 75742 - DE- N

NRTL

UL 1459

CSA Certified:

LR62298

DOC /CSO3:

1653 5663 A

TR 62411

Environmental

Operating Temp:

0° to 50° C (32° to 122°F)

Storage Temp:

- 20° to 85° C (- 4° to 185°F)

Humidity:

95% max (non - condensing)

Front Panel Description