Installation Instructions

For Part Numbers:

300-191

700-445 Airaid Oiled Media Filter

301-191

701-445 SynthaMax Dry Media Filter - Red

302-191

702-445 SynthaMax Dry Media Filter - Black

303-191

703-445 SynthaMax Dry Media Filter - Blue

2006-07 Dodge Ram 1500
4.7L V8 (With Hood Mat)

2. Unlatch 4 clips on the factory airbox lid and
remove the lid and intake hose assembly. Re-
move the factory air filter.

3. Squeeze the tab on the connector, and dis-
connect the air intake temperature sensor on
the back of the resonator.

4. With a 10mm socket, remove two bolts hold-
ing the intake resonator to the intake manifold
brackets.

5. Lift the front of the resonator straight up, and
then pull towards you to remove it from the
vehicle.

6. Gently twist the air temperature sensor
counterclockwise and remove it from the
resonator.

7. Install the supplied grommet (#10) into the
Modular Intake Tube (#3). Next, carefully slide
the factory temperature sensor into the grom-
met until it touches the tab on the temperature
sensor.

8. Install the Cool Air Dam (#2) onto the factory

airbox base by sliding the tabs on the base thru
the CAD and then adjust the sides to fit. Re-
latch the 4 clips to hold the CAD securely in
place.

9. Install the urethane hump hose (#4) onto
the tube on the CAD using two #60 hose
clamps (#7). Leave clamps loose.

Component Identification

1.

Airaid Premium Filter

1

2. Cool Air Dam

1

3. Modular Intake Tube

1

4. Urethane Hump Hose

1

5. Weather Strip 32 3/4”

1

6.

#56 Hose Clamp

1

7.

#60 Hose Clamp

2

8.

#14 Speed Clamp

1

9.

#24 Speed Clamp

1

10.

Rubber Grommet

1

11.

Black Rubber Cap

1

10. Install a #56 hose clamp (#6) on the facto-
ry throttle body coupler. Leave loose for now.

11. Install the Modular Intake Tube (#3) into
the hump hose first and then into the factory
coupler. Adjust for fit, and then tighten all 3
hose clamps.

12. Install the provided #24 speed clamp
(#9) over the factory breather hose, then
slide the hose onto the nipple on the CAD.
Squeeze the clamp to secure the hose.

1. Disconnect the negative battery cable!
Loosen the hose clamp on the resonator. Dis-
connect the breather hose going into the facto-
ry airbox lid.