2.6 Setting Dome Camera Protocol and Video

If a dome camera is to be installed with the keyboard controller, select the default protocol.

Consult service personnel if a dome camera is installed with device other than a keyboard
controller.

S2

You can set video type with DIP switch.

Select video type with D1 in S2.

You can set Protocol with DIP switch D2, D3 and D4 in S2.

S2

P

ROTOCOL

D2

D3

D4

OFF

OFF

OFF

F2, F2E, Pelco-P, Pelco-D : default

OFF

OFF

ON

F2, F2E

OFF

ON

ON

Pelco-P, Pelco-D

You can set Baud Rate with DIP switch D5 and D6 in S2.

S2

B

AUD

R

ATE

D5

D6

OFF

OFF

2400 bps

OFF

ON

4800 bps

ON

OFF

9600 bps : default

ON

ON

19200 bps

Figure 5 – Video type, Protocol, Baud rate Selection Switches

S2-D1

V

IDEO TYPE

OFF

NTSC

ON

PAL