Compliance requirements, Labeling requirements, Safety and compliance – Linx Technologies FCTN-WALL-xxx User Manual

Page 4: Underwriters laboratories (ul)

Advertising
background image

Page 7

Page 6

This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

In order to maintain compliance with FCC regulations, shielded cables must be used
with this equipment. Operation with non-approved equipment or unshielded cables
is likely to result in interference to radio and TV reception. The user is cautioned that
changes and modifications made to the equipment without the approval of
manufacturer could void the user’s authority to operate this equipment.

COMPLIANCE REQUIREMENTS

The AC Function Module has been tested by an FCC-approved facility and been
found to comply with all applicable FCC and Industry Canada requirements as of
the date of this document. A Declaration of Conformity (DoC) is on file. It is the
user’s responsibility to determine if any additional regulatory or safety testing will
be required on the user’s completed product. In products where no additional
testing is required, no further labeling of the unit is needed unless the module will
be placed inside another housing. It is, however, necessary to include the
following statement in the end product’s instruction manual or insert card.

Place the above statement in the instruction manual or insert card.

LABELING REQUIREMENTS

In cases where the FCTN-WALL-*** module is incorporated inside a product and
its standard labeling is not visible, the end product must be labeled as shown.

The label shall not be a stick-on paper label. The label shall be “permanently affixed” to the device
(meaning the label is etched, engraved, stamped, silk-screened, indelibly printed on a permanently
attached part of the device, or on a nameplate fastened to the equipment by welding, riveting, or a
permanent adhesive). The label must be designed to last the expected lifetime of the equipment in
the environment in which the equipment may be operated and may not be readily detachable.

When the device is constructed in two or more sections connected by wires and marketed together,
the label is required to be affixed only to the main control unit.

Function Wall Module

FCTN-WALL-***

SAFETY AND COMPLIANCE

The AC Function Module has been designed and tested to meet certain safety
and compliance standards. Please read, understand, and follow all safety and
compliance messages within this guide and check to ensure that the standards
to which the product has been tested are appropriate for your intended use.

UNDERWRITERS LABORATORIES (UL)

The AC Function Module has been tested by Underwriters Laboratories (UL

®

) for

compliance with the following standards:

UL 244A UL 916 CSA C22.2 #24-93

The AC Function Module is UL

®

listed for indoor operation only as a solid-state

appliance control. Operation in environments or applications other than those
associated with the above is not recommended.

The use of the UL

®

mark is protected, and may be used only by the original

licensee. Linx offers a full customization program for our valued OEM partners
that is designed to maintain compliance with use of the UL

®

mark. The UL

®

mark

may not be placed on labels or graphics for this product not originating from Linx.

End user manuals for the AC Function Module should indicate that no user
serviceable parts are contained inside the unit. The end user manual should not
contain replacement fuse information or other internal diagrams. A service
manual, however, may contain complete fuse information, and should be
accompanied by the following statement:

WARNING: To reduce the risk of electrical shock, replace only with the
same type and rating of fuse.

A service manual may reference the following approved replacement fuses only:

Littelfuse p/n 326025, 25A, 125V, slow blow

Schurter p/n 7043.8230, 20A, 250V, time lag

Cooper Bussman p/n MDA-20-R, 20A, 250VAC, time delay

Littelfuse p/n 314025, 25A, 250 V, Fast Acting

*** = frequency