Maintenance, Technical details, Powx1735 – Powerplus POWX1735 COMPRESSOR 1500W 24L LUBRICATED EN User Manual

Page 7: 8 maintenance, 9 technical details

Advertising
background image

POWX1735

EN

Copyright © 2014 VARO

P a g e

| 7

www.varo.com

 Always pull out the plug and drain the receiver once you have completed your work

(figures 10-11)

8 MAINTENANCE

 Before carrying out any operation, always pull out the plug and drain the receiver

completely (figures 10-11)

 Check that all screws ( in particular those of the head of the unit) are tightly drawn up. The

check must be carried out prior to the first compressor starting.

 After loosening any safety screws (fig. 12a), clean the intake filter according to the type of

working environment and at least every 100hours (figures 12b-12c). if necessary, replace
the filter element (clogging of the filter reduces compressor performance and an inefficient
filter causes increased wear).

 For lubricated models, replace the oil after the first 100 hours of operation and every 300

hours sebsequently (figures 13a-13b-13c). remember to check the oil level at regular
intervals.
Use API CC/SC SAE 40. (for cold climates, API CC/SC SAE 20 is recommended). Never
mix different grade oils. If the oil changes color (whiish = presence of water, dark =
overheated), it is good practice to replace the oil immediately.

 Periodically (or after working with the compressor for more than an hour), drain the

condensate that forms inside the receiver (fig. 11) due to the humidity in the air. This
protects the receiver from corrosion and does not restrict its capacity.

 Spent oil (lubricated models) and condensate MUST BE DISPOSED OF in accordance

with environmental protection regulations and current legislation.

Table 1

– Maintenance

Function

After the first 100 hours

Every 100 hours

Every 300 hours

Cleaning of intake filter
and / or substitution of
filtering element

Change of oil*

Tightening of head
tension rods

The check must be carried out prior to the first compressor
starting

Draining tank
concensate

Periodically and at the end of work.

* For lubricated models only

9 TECHNICAL DETAILS

Rated voltage

220-240 V~

Rated frequency

50 Hz

Rated Power

1500W / 2HP

Rotation speed

2850 min

-1

Rated Pressure

8 bar / 116 PSI

Tank capacity

24 l

Air debit (capacity)

222 l/min

Weight

25 kg

Cylinder

1

Lubricated

Yes

Advertising