47

DTR-60XX

Setup menu (continued)

Event – Alarm-In

On the “Alarm-In” menu the alarm inputs and responses to events are configured.

Setup Menu...

Event

Alarm-In

Settings

Term

Symbol

Meaning

No.

Enables the alarm inputs

Title

Name of alarm input

Type

Contact method of alarm input:
NO

Normally Open

NC

Normally Closed

Setup Menu...

Event

Alarm-In

Actions 1

Term

Symbol

Meaning

No.

Number of alarm input

Record

Assignment of cameras to record in event of alarm
These cameras must be in “Event” or “Time and Event” mode within

the time slot:
Setup Menu... > Record > Schedule

Alarm-Out

Assign and enable

alarm outputs

internal beep by DVR

These alarm outputs and the internal beep must be enabled within

the time slot:
Setup Menu... > Devices > Alarm-Out > Schedule

Notify

Assign and enable notifications:
Mail
Modem
LAN 1 to LAN 5
Alert Window
The selected function must be enabled:
Setup Menu... > Network > Notification