E

Controlling the Monitor with a PC (RS-232C)

n

Response code format

When a command has been executed correctly

O

K

Return code

(0D

H

, 0A

H

)

A response is returned after a command is executed.

When a command has not been executed

R

R

E

Return code

(0D

H

, 0A

H

)

TIPS

• “ERR” is returned when there is no relevant command or

when the command cannot be used in the current state of

the monitor. “ERR” is also returned when return code only

is sent without any command.

• If communication has not been established for reasons

such as a bad connection between the PC and monitor,

nothing is returned (not even ERR).

• “ERR” may be returned when a command cannot be

received correctly due to interference from the surrounding

environment.

Please ensure that the system or software retries the

command if this occurs.

n

Communication interval

• After OK or ERR is returned, you must send the following

commands.

To set a timeout for the command response, specify 10

seconds or longer.

• Provide an interval of 100 ms or more between the

command response and the transmission of the next

command.

VOLM0020
OK

CONT0001
OK

Interval of 100 ms or more