The first filter of the system is the 5-micron sediment

filter where the solid particles are retained. The

water from the sediment filter is passed through the

carbon filter. Granular Active Carbon (GAC) filter

retains organic matter especially free chlorine and

eliminates unwanted odors, carbon and other

particles that may escape from the filter, is passed

through the 1 micron Sediment Filter and it is

ensured that the pre-membrane filter is even more

suitable. This is also a factor affecting the life of the

membrane. The water cleaned in three pre-filters,

solid ions dissolved in the membrane that is the

basis of the RO water treatment system, small

particles, bacteria, viruses are retained to a large

extent and given to the waste water. Among these

ions are many ions such as heavy metals, sodium,

lead, arsenic, nitrate, asbestos, etc. While the waste

water containing the undesirable substances are

discharged from one line of the membrane running

with cross-flow method, water received from the

other line of the cross-flow is collected in a pressur-

ized tank. The amount of waste water should always

be more than the clean water so that the membrane

works in a healthy way and has a long life. Through

the ready the water in the tank, water is supplied

faster. Your appliance's tank capacity is 8 litres

(approximately 2.2 gallons).

This appliance certified for the purification of microor-

ganisms can also be used in waters that contain microor-

ganisms although it has been disinfected.

Aura Cebilon Reverse Osmosis System contains critical

components that are required to be replaced periodical-

ly to purify the total dissolved solid materials (TDS)

efficiently. To check the efficiency of the system, water

from the appliance must be periodically tested.

Your appliance contains critical components that must

be replaced periodically with respect to the system's

efficiency. These critical components must be replaced

with components and filters with the specifications

defined by the manufacturer so that the system can

operate continuously with the same efficiency and

performance.

Operating

principle

BOX SIZE (mm)

580x277x450

8 L (100 psi/689 kPa)

TANK CAPACITY

6-7 psi (40-48 kPa)

AIR TANK PRESSURE

75,15 gpd (284,47 L/day)

DAILY CAPACITY ***

%85-%98

PURIFICATION RATE ***

30,93%

EFFICIENCY RATIO ***

34,89%

RECYCLING RATE ***

0,8 L/dk-1,2 L/dk

PUMP FLOW RATE **

80 psi-110 psi (551-758 kPa)

PUMP PRESSURE**

24 V DC

POWER SUPPLY PUMP**

425x490x260

DEVICE SIZE (mm)

14,5 kg (101 ME) 14 kg (101 MD)
11 kg (101 FG)

TOTAL WEIGHT

TANK SIZE

Diameter: 24.4 cm Height: 36.6 cm

** Valid for 101 ME and 101 MD models
*** Valid for 101 ME model

Technical specifications