Interface – Erica Synths Hexinverter Mutant Brain MIDI to CV Eurorack Module (8 HP) User Manual

Page 4

Advertising
background image

24.April.2018

Mutant Brain user manual v1.00

PG4

Hexinverter Électronique, 2018

INTERFACE

Connectors

Mutant Brain has the following connections:

A standard 5-pin MIDI input socket

Four 3.5mm jack sockets, labelled A through D, which output analog
control voltage signals

Twelve 3.5mm jack sockets, labelled 1 through 12, which output
digital gate signals

LEDs

Mutant Brain has 18 LED indicators:

The LED to the left of the MIDI port indicates MIDI activity

The LED to the right of the MIDI port usually indicates presence of a
MIDI clock and blinks on each beat. Some other actions use this LED
to show special statuses. These will be described later.

The 4 LEDs next to the CV outputs change brightness based to
indicate the voltage they are receiving.

The 12 LEDs next to the gate outputs flash when they receive a gate
or trigger.

Button

Mutant Brain is highly configurable, but all changes must be made over MIDI.
In fact, there is only one button on the module!

Press and release the button to reset all the outputs

. This will:

Clear all held MIDI notes

Turn off all gates (see note)

Set all CV outputs to zero (see note)

Reset note cycle modes to the first note

Reset clock dividers

The top right LED port blinks once when the reset is registered

A CV mapped to a pitch bend will go to it half-voltage position (no bend) on reset

A CV mapped to a fixed voltage will not reset

An “all notes off” gate will be triggered

The button also has a special use at power up so that new firmware can be uploaded.

This process will

be described later.

After you have uploaded a new Sysex Patch you can save it by pressing and holding the button for 2". When

the patch is saved it will be automatically loaded after the power cycle.