background image

Model Description

Rio Rancho, NM

3

IMPORTANT: Connect the cable into the receiver

or microphone and make sure it is working before

crimping the cable clamp.

Slide the cable clamp into the hous-

ing, making sure the tab seats in the

keyway on the housing. Gently push

the cable into the housing to leave a

little slack in the wires before crimp-

ing.

DO NOT ROTATE THE

CONNECTOR SLEEVE MORE

THAN 90 DEGREES IN TRYING

TO ORIENT THE CABLE EXIT

DIRECTION.

Step 6

Crimp the tabs on the cable clamp.

If it is necessary to ground the

housing to the cable, use the

smaller cable clamp tabs to grab the

cable shield. The larger tabs should

always go over the cable insulation and the tubing to

keep the insulation from working up the cable. The

housing will normally ground to the transmitter case

through the retainer, but some lavalieres really like to

have the cable clamp tabs grab the shield for better RF

rejection.

Step 7

Slide the backshell over the clamp and thread it onto

the housing.

Smaller

crimping tabs

Larger

crimping tabs

Silicon

tubing

Backshell

(modified or standard)

Metal

retainer

Plastic

spacer

Insert

(3-pin or 5-pin)

Connector

sleeve

Tab in keyway

NOTE: Larger silicon tubing is normally positioned over

the cable clamp after it is crimped. Smaller silicon tubing is

normally positioned under the cable clamp before it is crimped.

Also see Step 6 below about grounding of some lavaliere mics.

Step 1

Install the set screws into the right angle housing. Turn

them in a few turns, but do not tighten them. Slide all

the parts onto the cable in the order shown above.

Step 2

Strip the outer insulation of the cable back about 1/2

inch. Strip the insulation on the inner wires back about

1/8 inch.

Step 3

Solder the wires onto the pins on the insert as needed.

For the SR receiver, refer

to its manual for pinouts.

http://www.lectrosonics.

com/manuals/SRman.pdf

For microphones to be

used with Lectrosonics transmitters, refer to the Servo

Bias Mic Wiring document.

http://www.lectrosonics.com/service/ServoBiasWiring.pdf

Step 4

Slide the spacer up, align the flats on it and then attach

it to the insert. Make sure the metal retainer is in posi-

tion on the plastic spacer and slide the assembly into

the connector sleeve. The flats must be aligned with

the black button on the sleeve for the assembly to fully

nest inside the sleeve.

Step 5

Orient the connector sleeve in the desired position

while the cable can freely rotate inside the housing.

Gently slide

the cable and

connector as-

sembly back

through the

housing until

the connector

is seated.
Apply pressure to make sure the connector assembly

is completely seated in the housing. Insert the long

end of the allen wrench and tighten the two set screws

to secure the connector sleeve.

1/2”

1/8”

Shield

Align flats with button