Ilford Delta 3200 Black and White Negative Film (120 Roll Film) User Manual

Page 6

Advertising
background image

Page 6 of 7

Nov 2018

DELTA 3200 PROFESSIONAL

Technical Information

PROCESSING

DELTA 3200 Professional can be processed in all types of processing equipment including spiral tanks, rotary

processors, dishes/trays, deep tanks and automatic processors. Standard capacity figures and replenishment
rates can be maintained. When fixing DELTA 3200 Professional however, slightly longer times than used with

conventional film are recommended for best results.

Safelight recommendations

Handle DELTA 3200 Professional film in total darkness.

Agitation

Intermittent agitation is recommended for use in spiral tanks and deep tanks. With spiral tanks, invert the tank
four times during the first 10 seconds, then invert the tank four times again during the first 10 seconds of each

further minute. Otherwise, follow the recommendations given by the processing equipment manufacturer.

Stop, fix, wash and rinse

For best results it is recommended that all process solutions are kept at the same temperature or at least within

5ºC (9ºF) of the developer temperature.

Stop Bath

After development the film can be rinsed in

water, but we recommend that an acid stop
bath is used such as ILFORD ILFOSTOP (with

indicator dye). ILFORD ILFOSTOP is also
recommended for all machine processing

applications. When tanks or dishes (trays) of
process solutions are in use, a stop bath

immediately stops development and reduces
carry over of excess developer into the fixer

bath. This helps to maintain the activity and
prolong the life of the fixer solution.


The process time given is the minimum required, if necessary, a longer time may be used and should not cause

any process problems provided it is not excessive.

Fix

The recommended fixers are ILFORD RAPID

FIXER or ILFORD HYPAM FIXER.

Wash

Wash the films in running water for 5–10
minutes at a temperature within 5ºC (9ºF) of

the process temperature. Or see note below
for greater economy when using spiral tanks.

Note:

For spiral tank use, the following method of washing is recommended. This method of washing is faster,

uses less water yet still gives negatives suitable for long term storage.
After fixing, fill the spiral tank with water at the same temperature, +/– 5ºC (9ºF), as the processing solutions

and invert it five times. Drain the water away and refill. Invert the tank ten times. Once more drain the water
away and refill. Finally, invert the tank twenty times and drain the water away.

ILFORD ILFOSTOP

Dilution 1+19

Temperature Range

18–24ºC (64–75ºF)

Time (sec) at 20ºC (68ºF)

10

Capacity (films per litre,

unreplenished)

15x (135-36)

ILFORD RAPID OR HYPAM FIXERS

Dilution 1+4

Temperature Range

18–24ºC (64–75ºF)

Time (mins) at 20ºC (68ºF)

2-5

Capacity (films per litre,

unreplenished)

24x (135-36)