Ilford Pan F Plus Black and White Negative Film (120 Roll Film) User Manual
Page 4
Page 4 of 6
Nov 2018
PANF PLUS
- Technical Information
PROCESSING
Development Times
If PAN F Plus has been inadvertently
exposed at settings below EI 25/15 or
above EI 64/19, the following guide will
ensure usable negatives are obtained.
Obviously, the quality of negatives
processed in this way will not be so high
as conventionally processed ones.
Note
Development times may need adjusting to suit individual processing systems and working practices. If an
established system is producing development times until the desired contrast level is obtained. Development
times in other manufacturers’ developers are included for your convenience and are only a general guide.
Other manufacturers can and do change their product specifications from time to time, and the development
times may change as a result.
Processing at Different Temperatures
PAN F Plus film can be processed over a range of temperatures. Development times at temperatures other than
20°C/68°F may be calculated from the chart below. For example, if 4 minutes at 20°C/68°F is recommended,
the time at 23°C/73°F will be 3 minutes and the time at 16°C/61°F will be 6 minutes.
PAN F Plus roll film developed in ILFORD ILFOTEC HC (1+31) for 4
minutes at 20°C/68°F with intermittent agitation. This curve is also
representative of the 35mm film format.
Manual Processing (min @ 20°C/68°F) – accidental
exposure only
Ilford
Developer Dilution Meter
Setting
EI 12/12
and below
EI 100/21 EI 200/24
and above
Microphen Stock
-
8
12
ID-11
Stock
4
-
-