Ilford SFX 200 Black and White Negative Film (35mm Roll Film, 36 Exposures) User Manual

Page 4

Advertising
background image

Page 4 of 6

Nov 2018

SFX 200

Technical Information

35mm and Roll Film

ILFORD developer Dilution

Meter setting (EI)

200/24 400/27 800/30

Spiral tank, deep tank, dip and dunk machines (min/20

°

C/68

°

F)

ILFOTEC DD-X

1+4

10 14

ILFOSOL 3

1+9

6

--

1+14

9

13½

ILFOTEC HC

1+15

5 7 10½

1+31

9

13 19

ILFOTEC LC29

1+9

5

7

10½

1+19

9

13

19

1+29

11

ID-11

stock

10

14

18

1+1

17

MICROPHEN

stock

10½

14½

1+1

15½

19

PERCEPTOL

stock

14½

1+1

20

_

Non-ILFORD Developers (min/20

°

C/68

°

F)

Developer

Dilution

Meter setting (EI)

200/24 400/27 800/30

Kodak D-76

stock

10

12½

16½

1+1

14½

Kodak HC-110

A

5 7 10½

B 9

13 19

Kodak T-Max

1+4

8½ 10½ 12½

Tetenal Ultrafin

1 + 10

10

13

Kodak Xtol

stock

7

11

Dip and dunk machines (min/24°C/75°F)

ILFOTEC DD

1+4

11½

14

Kodak T-Max RS

stock

6

7

9

Kodak Xtol

stock

7

9

11½

ILFOLAB FP40, roller transport and short leader machines (sec/26°C/79°F)

ILFOTEC RT RAPID

1+1+2

54

65

88

1+1+5

65

90

120

Note.

Development times may need adjusting to suit individual processing systems and working practices. If an

established system is producing good results, adjust the recommended development times until the desired
contrast level is obtained. Development times in other manufacturers’ developers are included for your

convenience and are only a general guide. Other manufacturers can and do change their product
specifications from time to time, and the development times may change as a result.