'ĞƚͲ&ƵŶĐƟŽŶ>ŝƐƟŶŐ

dŚĞWĐĂŶŝŶƚĞƌƌŽŐĂƚĞƚŚĞ>&ĨŽƌƐƉĞĐŝĮĐŝŶĨŽƌŵĂƟŽŶ͘dŚĞ'ĞƚͲ&ƵŶĐƟŽŶƉĂĐŬĞƚ
ĨŽƌŵĂƚĐŽŶƐŝƐƚƐŽĨϵďLJƚĞƐǁŚŝĐŚŝƐƐŝŵŝůĂƌƚŽƚŚĞ^ĞƚͲ&ƵŶĐƟŽŶƉĂĐŬĞƚƐƚƌƵĐƚƵƌĞ͘

Note that the “Value” byte is always = 000.

'ĞƚͲ&ƵŶĐƟŽŶĞƐĐƌŝƉƟŽŶ͗

Length:

Total Byte of Message excluding “CR”.

TV/DS ID

Identification for each of TV/DS (01~98; default is 01).

Command Type

Identify command type,
“g” (0x67h) : Get Command
“r” (0x72h) : Valid command Reply
“-“ (0x2Dh) : Invalid command Reply

Command:

Function command code: One byte ASCII code.

Value[1~3]:

Three bytes ASCII that defines the value.

CR

0x0D

'ĞƚͲ&ƵŶĐƟŽŶ&ŽƌŵĂƚ
^ĞŶĚ͗;ŽŵŵĂŶĚdLJƉĞс͞Ő͟Ϳ

Name Length

ID

Command

Type

Command Value1 Value2 Value3 CR

Byte

Count

1 Byte

2

Byte

1 Byte

1 Byte

1 Byte 1 Byte 1 Byte

1

Byte

Bytes
order

1

2~3

4

5

6

7

8

9

ZĞƉůLJ͗;ŽŵŵĂŶĚdLJƉĞс͞ƌ͟Žƌ͞Ͳ͟Ϳ

If the Command is valid, Command Type = “r”

Name Length

ID

Command

Type

Command Value1 Value2 Value3 CR

Byte

Count

1 Byte

2

Byte

1 Byte

1 Byte

1 Byte 1 Byte 1 Byte

1

Byte

Bytes
order

1

2~3

4

5

6

7

8

9

/ĨƚŚĞŽŵŵĂŶĚŝƐEKdǀĂůŝĚ͕ŽŵŵĂŶĚdLJƉĞс͞Ͳ͟

Name Length

ID

Command

Type

CR

Byte

Count

1 Byte

2 Byte

1 Byte

1 Byte

Bytes
order

1

2~3

4

5

Advertising