Ca series getting started – Lab.gruppen CA1202 2 x 120W Commercial Amplifier User Manual

Page 7

Advertising
background image

12

CA SERIES

Quick Start Guide

13

CA Series Getting started

Welcome to the CA series Quick Start Guide and thank you for purchasing one of

these amplifiers. The following accessories should be included with your product:

Euroblock input connector(s)

Euroblock output connector

Coupling plate (x2) with necessary screws

Long angle bracket

Front angle bracket (x2)

Rear flat bracket

Rear angle bracket with shoulder screw

Power cable with mains plug corresponding to the specified country version

Quick Start Guide (this document)

Rack Mounting

The CA series amplifiers come with rubber feet that enable the amps to be

placed on a clear surface without an additional installation. However, optional

rack mounting hardware is also supplied, allowing several models to be housed

and protected inside an enclosure. Follow these steps to attach the mounting

hardware.
A pair of CA units can be mounted side-by-side to occupy a single rack space.

Attach the coupling plate to the underside of 2 CA units using the included

screws.

Attach the front angle brackets to either side of a pair of CA units that have been

coupled. Alternatively, a single CA unit can be installed in a 19" rack using the

long angle bracket, or in a half

19" rack using the short angled brackets.
Attach the angled brackets, by unscrewing the chassis side front screws and

attach again together with the brackets.

If your rack has rear rails, attach the rear flat brackets by reusing the screws from

the chassis.

Mount the CA units into the rack by attaching 4 rack screws through the front

angle brackets and rack rails.
Hold one of the rear angle brackets up to the rear rack rails so that it lines up next

to the rear flat bracket. Do not attach it to the rear rails yet.
Insert the included shoulder screw through the slot in the rear flat bracket and

into one of the threaded holes in the rear angle bracket. The screw should allow

the rear angle bracket to slide forward and back within the flat bracket’s slot.

Repeat the process for the other rear angle bracket.
Mount the rear angle brackets to the rear rack rails using 4 standard rack screws.
Tighten the shoulder screw if necessary.
The standard rack screw is M4 x 8mm.
The CA series amplifiers are convection cooled and primarily use the top surface

to dissipate heat. For demanding applications, it is recommended to have

sufficient space (1 RU) above the amplifier to reduce the risk of limiting due to

overheating.

Table/Wall Mounting

Connect a pair of coupling plates to either side of a CA series amplifier, then

mount screws through the remaining holes in the plates to secure the unit to a

wall or table.

Connections

For balanced input connections, use a 3-pole cable (hot, cold, ground) wired to a

Euroblock connector. Alternatively, RCA cables can be connected for unbalanced

stereo sources, but the RCA and Euroblock inputs should not be used together on

the same input. Note that stereo RCA signals will be summed to mono.

For output signals, connect a 4-pole (2-pole for CA601/1201/2401) Euroblock

connector to the main output connector. Do NOT connect any terminal to ground.

Do NOT connect the cold (-) terminals together for common returns. Make sure to

set the Config switches in the correct position to match your intended use.

Speaker wire of 14-18 AWG (0.8 to 2.5 mm) is recommended for connections up

to 50 feet.

Config

The first 2 Config dipswitches allow the output to be configured for 100 V, 70 V, 8

Ω, or 4 Ω operation. Always use the correct configuration for the speakers being

driven! The mode of operation configures both the maximum voltage of the

output and the gain through the device.
The 8 Ω setting should be used for a pair of 16 Ω speakers or a single 8 Ω speaker.

The 4 Ω setting should be used for 4 x 16 Ω, 2 x 8 Ω, or a single 4 Ω speaker. Use 70

or 100V setting for Constant Voltage high impedance speaker systems. Make sure

the sum of the power tapping on the speakers plus margin does not exceed the

amplifier's maximum power rating.
The 3rd dipswitch engages a high-pass filter at 80 Hz, which should be used on

all Constant Voltage systems to avoid saturation on the transformer-enabled

speakers, but can also be used to help maintain clear sound from small speakers

or bass-heavy audio.

Remote

RJ45 receptacle to connect an optional remote volume control per channel.

Use a standard cable to connect the CRC-V accessory. Or connect a custom

potentiometer with the pinout information. Cable length above 305m (1000ft) is

not recommended.

Signal Wake-up

If the amps are powered on, but do not receive any input signal (below signal

present level) for 20 minutes, the system will enter standby mode to save power

consumption. As soon as a signal is detected at any input, the unit will exit

standby mode and resume normal function.

3-Pin Euroblock Connector - Input

1

2

3

1. hot (+)

2. cold (-)

3. ground/shield

1

2

3

4

1. Out A - hot (+)

2. Out A - cold (-)

3. Out B - hot (+)

4. Out B - cold (-)

RJ-45 Pin

Color

(T568B)

Remote

(1 channel

products )

Remote

A+B

Remote B

1

White/

Orange

VCC 10V

VCC 10V

VCC 10V

2

Orange

Volume

Control

Volume

Control

Channel A

Volume

Control

Channel B

3

White/Green

N/A

Volume

Control

Channel B

N/A

8

Brown

Ground

Ground

Ground

Advertising