Henny Penny CMC/CMR-107 User Manual

Henny Penny Freezers

Advertising
background image

Henny Penny

Model CMC/CMR-103,104,105,106,107

3-1. INTRODUCTION

This section provides explanations of all controls, along
with operating procedures and daily maintenance. Read the
Introduction, Installation and Opeation Sections before
operating the unit.

Wait at least 4 hours before plugging the unit into an
electrical supply. The gases and oils in the refrigeration
system needs to settle before operating the compressor, or
damage to the compressor could result.

3-2. OPERATING CONTROLS

Refer to figure 3-1.

Fig.

Item

Description

Function

No.

No.

3-1

1

Power Switch

Turns electrical power off and on to the unit; located on the

bottom of the control panel

3-1

2

Digital Display

Shows the temperatures and the information in the Technical
Mode

3-1

3

Used to increase setpoint values, as well as programming
values; also, automatic defrost cycles are programmed in
the controls, but to manually start a defrost cycle, press and
hold for 3 seconds to start a manual defrost cycle;

“DEF/SET’ shows in display

3-1

4

Used to decrease setpoint values, as well as programming
values

3-1

5

Press to view the setpoint temperature, or hold it for it for 4
seconds to enter the program mode; once in the Program
Mode, press to view other parameter setpoints;

Press , along with and to change the
parameters

SECTION 3. OPERATION

3-1

303

Advertising
This manual is related to the following products: