Troubleshooting

135

SSL1016 Tape Autoloader Reference Guide

A8

Destination element

full

Verify the expected destination really does not have

a cartridge.

If destination is a magazine, install and remove a

cartridge from the selected slot and try again. If

error continues, replace the magazine.

If destination is the tape drive verify the tape drive

does not have a cartridge.

If a cartridge is in the mailslot opening, remove it

and verify that the mailslot door is closed.

Power cycle the autoloader.

Set the autoloader to Home using Web

Administration, Command page.

Run the Health test.

If error continues, contact HP customer support.

A9

Picker full

Look in the front of the autoloader and confirm the

picker is full.

Power cycle the autoloader.

Run the Health test.

Set the autoloader to Home using Web

Administration, Command page.

Contact HP customer support if the problem

continues and prevents normal operations.

AA

Picker cartridge

sensor error

Perform picker test.

Perform the Health test.

If problem prevents the test from running, contact

HP customer support.

AB

Drive path sensor

error

Run the Health test.

Power cycle the autoloader.

AC

Mail slot door sensor

error

Insert a cartridge into the autoloader via the mail

slot.

Power cycle the autoloader.

Table 14: Error Messages