Caution, Yhu\7r0rqwkv 'hshqglqjrq:dwhu4xdolw, Qgri+xplglilfdwlrq6hdvrq – Honeywell HE360A User Manual

Page 7: Hjlqqlqjri+xplglilfdwlrq6hdvrq

Advertising
background image

HE360A,B POWERED FLOW-THROUGH HUMIDIFIER

7

68-0194—2

Table 2. Recommended Frost Factor Adjustment.

Humidity Level

Recommended Setting

Insufficient humidity

Increase the frost factor dial be one setting

Condensation on windows

Reduce the frost factor dial by one setting.

0$,17(1$1&(

A regular maintenance program prolongs the life of the
humidifier and provides a more comfortable environment.
Frequency of cleanings depends on water conditions.

Either hard or soft water can be used in the humidifier, but
hard water mineral deposits are more difficult to clean then
soft water deposits.

Use the following procedure to clean the humidifier.

CAUTION

Personal Injury or Equipment Hazard.
Power Supply can cause electrical shock or
equipment damage.
Disconnect power supply before performing
humidifier maintenance.

IMPORTANT

Never oil any part of the humidifier.

(YHU\7R0RQWKV

'HSHQGLQJRQ:DWHU4XDOLW\

1. Disconnect the power and turn off the humidifier

water supply.

2. Remove the humidifier cover. See Fig. 11.

M12809

COVER
ASSEMBLY

HUMIDIFIER
PAD ASSEMBLY

FEED TUBE NOZZLE

WATER
DISTRIBUTION TRAY

HUMIDIFIER
HOUSING

THUMB
SCREW

Fig. 11. Location of humidifier parts.

3. Remove the humidifier pad assembly from the

humidifier by grasping the tray and pulling it toward
you.

4. Pull one side of the humidifier pad assembly frame

toward you and remove the tray from the frame.

5. Gently pinch the water nozzle catches inward until

the water nozzle can be lifted off the tray.

6. Slide the humidifier pad out of the frame.
7. Carefully scrape any mineral deposits from the tray

and frame. Be sure the frame drain hole has nothing
blocking it.

8. Check the humidifier pad and if excessive mineral

deposits are present, replace with a new pad.

9. Disconnect the drain hose from the drain fitting on

the bottom of the humidifier housing.

10. Clean the drain fitting, if necessary.
11. Bend the drain hose to loosen any mineral deposits.
12. Flush the drain hose with pressurized water (a

running tap) to clean the hose.

13. Reattach the drain hose to the drain fitting.
14. Slide the humidifier pad back into the frame.

IMPORTANT

Be sure the marked end of the humidifier pad is
facing up for proper performance.

15. Reattach the tray to the frame.
16. Snap the water nozzle back on the tray.
17. Place the humidifier pad assembly in the humidifier

housing and press until the assembly is seated.

18. Be sure the water feed tube is placed in the guide

slots of the humidifier housing.

19. Replace the humidifier cover.
20. Verify the humidifier operation by following the steps

in the Checkout Procedure section.

(QGRI+XPLGLILFDWLRQ6HDVRQ

The humidifier needs to be cleaned and shut off at the end
of the heating season. Follow steps 1 through 19 from the
Every 1 To 3 Months section.

IMPORTANT

Be sure the humidifier power is off.

%HJLQQLQJRI+XPLGLILFDWLRQ6HDVRQ

Refer to the Checkout Procedure section for complete
humidifier startup instructions.

Advertising