(34) SECURITY SET PASSWORD (F1h)

This command enables a user password or master password to be set.

The host transfers the 512-byte data shown in Table 5.13 to the device. The
device determines the operation of the lock function according to the
specifications of the Identifier bit and Security level bit in the transferred data.
(Table 5.14)

Issuing this command in LOCKED MODE or FROZEN MODE returns the
Aborted Command error.

Table 5.13 Contents of SECURITY SET PASSWORD data

Word

Contents

0

Control word
Bit 0 Identifier

0 = Sets a user password.
1 = Sets a master password.

Bits 1 to 7 Reserved
Bit 8 Security level

0 = High
1 = Maximum

Bits 9 to 15 Reserved

1 to 16

Password (32 bytes)

17 to 18

Master password version number

19 to 255

Reserved

Table 5.14 Relationship between combination of Identifier and Security level, and

operation of the lock function

Indentifier

Level

Description

User

High

The specified password is saved as a new user password.
The lock function is enabled after the device is turned off
and then on. LOCKED MODE can be canceled using the
user password or the master password already set.

Master

High

The specified password is saved as a new master password.
The lock function is not enabled.

User

Maximum

The specified password is saved as a new user password.
The lock function is enabled after the device is turned off
and then on. LOCKED MODE can be canceled using the
user password only. The master password already set
cannot cancel LOCKED MODE.

Master

Maximum

The specified password is saved as a new master password.
The lock function is not enabled.