1.1 Standard Features

C141-E234

1-3

When Write Cache is enabled, you should ensure that the cached data is
surely flushed to the disk media before you turn off the drive's power.

To ensure it, you should issue either the SYNCHRONIZE CACHE
command or the STOP UNIT command with specifying “0” to the
Immediate bit, and then confirm that the command is surely terminated
with the GOOD STATUS.



(9)

Command queuing feature

The HDD can queue maximum 128 commands, and optimizes the issuing order of queued commands
by the reordering function. This feature realizes the high speed processing.



(10)

Reserve and release functions


The HDD can be accessed exclusively in the multi-host or multi-initiator environment by using the
reserve and release functions.



(11)

Enclosure service function


The HDD supports the enclosure service interface (ESI), which complies with SFF-8067. The ESI
interface enables use of the SCSI-3 enclosure service command set (SES) so that the functions that
specify and read enclosure service information can be used.