First Alert ONELINK CO511 User Manual

First Alert Car alarm

Advertising
background image

USER’S MANUAL

Printed in Mexico

M08-0195-002 Q

09/10

1

2

3

ONELINK

®

BATTERY OPERATED

CARBON MONOXIDE ALARM

4

Model CO511

Features:

ONELINK

®

Enabled

Voice with Programmable Location
Two Latching Features
Two Silence Features

5

6

7

Printed in Mexico M08-0195-002 Q

09/10

IMPORTANT! PLEASE READ CAREFULLY AND SAVE.
This user’s manual contains important information about your Carbon
Monoxide Alarm’s operation. If you are installing this Alarm for use by others,
you must leave this manual—or a copy of it—with the end user.

BASIC SAFETY INFORMATION

• Dangers, Warnings, and Cautions alert you to important operating

instructions or to potentially hazardous situations. Pay special
attention to these items.

• This CO Alarm is approved for use in single-family residences.

• The CO Alarm is not designed to detect fire or any other gas. It will

only indicate the presence of carbon monoxide gas at the sensor.
Carbon monoxide gas may be present in other areas.

• This CO Alarm cannot operate without working batteries.

Removing the batteries for any reason, or failing to replace the
batteries at the end of their service life, removes your protection.

• NEVER ignore any alarm. See “If Your CO Alarm Sounds” for more

information on how to respond to an alarm. Failure to respond can
result in injury or death.

• The Silence Features are for your convenience only and will not

correct a problem. See "Using the Silence Features" for details.
Always check your home for a potential problem after any alarm.
Failure to do so can result in injury or death.

• Test this CO Alarm once a week. If the Alarm ever fails to test

correctly, have it replaced immediately! If the Alarm is not working
properly, it cannot alert you to a problem.

• This product is intended for use in ordinary indoor locations of

family living units. It is not designed to measure CO levels in
compliance with Occupational Safety and Health Administration
(OSHA) commercial or industrial standards. Individuals with
medical conditions that may make them more sensitive to carbon
monoxide may consider using warning devices which provide
audible and visual signals for carbon monoxide concentrations
under 30 ppm. For additional information on carbon monoxide
and your medical condition contact your physician.

WIRELESS OPERATION

First Alert

®

ONELINK

®

Technology is the easy, cost-effective way to provide

your family with whole-home safety. All ONELINK

®

Alarms communicate with

each other without wires or connectors. When one Alarm sounds, they all
sound. This provides your family with an earlier warning of potential danger,
and gives you more time to react.

The communication distance (range) between any two ONELINK

®

Alarms is

typically 50 feet (15 meters) inside of a home. Some features of a home, such
as the number of floors, number/size of rooms, furniture and types of building
materials used may reduce the range of the Alarms. Examples include:
suspended ceilings, ductwork, large metallic appliances (refrigerators) and
metal studs. A feature of ONELINK

®

Alarms is that they operate as a mesh

network. All Alarms will repeat any alarm signal that is received to all other
ONELINK

®

Alarms. Interference from structural conditions can be overcome

by adding additional Alarms to route the wireless signal around obstructions.

The range and proper operation of any wireless device will vary
depending on its surroundings. It is very important that each
Alarm is tested individually before and after installation to make
sure that all Alarms respond properly.

• The ONELINK

®

Alarms are not to be used outdoors or to transmit

between buildings. The Alarms will not communicate properly
under these conditions.

Metal objects and metallic wallpaper may interfere with signals
from wireless Alarms. Alarms should be tested after changes to
your home such as remodeling, moving furniture, and with metal
doors opened and closed.

Your First Alert

®

ONELINK

®

CO Alarm will automatically communicate both

potential fires and carbon monoxide presence with all other First Alert

®

ONELINK

®

Smoke/CO Alarms.

FCC NOTICE: This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This device may not
cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
FCC ID: M7U5001L

Changes or modifications not expressly approved by BRK Brands, Inc.
could void the user’s authority to operate the equipment.

INTRODUCTION

Thank you for choosing First Alert

®

for your Carbon Monoxide Alarm needs.

You have purchased a state-of-the-art Alarm designed to provide you with
early warning of a carbon monoxide danger. Key features include:

ONELINK

®

Enabled. Alarm automatically communicates with other ONELINK

®

enabled alarms when installed.

Exclusive Voice Warning with Location will tell you the preprogrammed
location of the initiating unit and danger detected. Programmable up to 11
locations (ex. "basement"). When alarms sounds, if programmed for basement
it will say "Warning, evacuate, carbon monoxide in basement" along with all
other installed ONELINK

®

Voice alarms.

Spread Spectrum Horn Tone. Lower and varying horn frequency makes it
easier for elderly with normal age related hearing loss to hear horn. Sweeps
through the 2200 – 3400 Hz range.

RF Interconnect. Reliable and secure radio frequency communication
between alarms. 915MHz frequency with 65,000 security codes and 3 channel
frequency hopping.

Single Button Test/Silence eliminates confusion. Depending on what mode
the alarm is in, pushing the button provides different functions such as testing
the alarm, silencing the alarm, re-testing the alarm when in silence and clearing
the Latching features.

Two Silence Features. Temporarily silence low battery chirp for up to eight
hours before replacing low battery or silence an unwanted alarm for several
minutes.

Two Latching Features. Alarm Latch: Easily identifies initiating alarm even
after alarm condition has subsided. Low Battery Latch: Identifies which unit
is in low battery condition.

Perfect Mount System includes a gasketless base for easy installation and
a mounting bracket that keeps the alarm secure over a wide rotation range
to allow for perfect alignment.

End of Life Signal. Provides audible confirmation alarm needs to be
replaced.

© 2010 BRK Brands, Inc. All rights reserved.
Distributed by BRK Brands, Inc.
3901 Liberty Street Road, Aurora, IL 60504-8122
Consumer Affairs: (800) 323-9005 • www.firstalert.com

TABLE OF CONTENTS

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

Basic Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

Wireless Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

Where to Install CO Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Where CO Alarms Should NOT Be Installed . . . . . . . . . . . . . . . . . . . . .2
How to Install This Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

Step By Step Guide to Programming This Alarm . . . . . . . . . . . . . . . . . .2-3

Adding and Linking Additional ONELINK

®

Alarms . . . . . . . . . . . . . . . . .3

What You Will See and Hear With This Alarm . . . . . . . . . . . . . . . . . . . .3

Weekly Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Optional Locking Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4
If Your CO Alarm Sounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Using the Silence Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Latching Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Regular Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
What You Need To Know About CO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

What is CO? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Symptoms of CO Poisoning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Finding the Source of CO after an Alarm . . . . . . . . . . . . . . . . . . . . . . . .5
Potential Sources of CO in the Home . . . . . . . . . . . . . . . . . . . . . . . . . .5

How Can I Protect My Family From CO Poisoning? . . . . . . . . . . . . . . . . .6
Regulatory Information For CO Alarms . . . . . . . . . . . . . . . . . . . . . . . . . .6-7

Underwriters Laboratories Inc. UL 2034 . . . . . . . . . . . . . . . . . . . . . . .6-7

General Limitations Of CO Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Troubleshooting Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-7
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-7

INSTALLATION

WHERE TO INSTALL CO ALARMS

The National Fire Protection Association (NFPA) recommends that a CO Alarm
should be centrally located outside of each separate sleeping area in the
immediate vicinity of the bedrooms. For added protection, install additional
CO Alarms in each separate bedroom, and on every level of your home.

If your bedroom hallway is longer than 40 feet (12 meters), install a CO Alarm
at BOTH ends of the hallway.

Refer to state and local building codes for additional requirements.

In a Single-level Home:

Install at least one CO Alarm near or within each separate sleeping area.

For added protection, install an additional CO Alarm at least 20 feet
(6 meters) away from the furnace or fuel burning heat source.

In a Multi-level Home:

Install at least one CO Alarm near or within each separate sleeping area.

For added protection, install at least one CO Alarm on each level of the
home. If you have a basement, install that CO Alarm at the top of the
basement stairs.

For added protection, install an additional CO Alarm at least 20 feet
(6 meters) away from the furnace or fuel burning heat source.

In Mobile Homes:

Install CO Alarms on inside walls ONLY. Uninsulated outside walls and
roofs of mobile homes often transfer heat and cold from outdoors.

WHERE CO ALARMS SHOULD NOT BE INSTALLED

Do NOT locate this CO Alarm:

In garages, kitchens, furnace rooms, or in any extremely dusty, dirty or
greasy areas.

Closer than 15 feet (4.6 meters) from a furnace or other fuel burning heat
source, or fuel burning appliances like a water heater.

Within 5 feet (1.5 meters) of any cooking appliance.

In areas where temperature is colder than 40˚ F (4˚ C) or hotter than 100˚ F
(38˚ C). These areas include unconditioned crawl spaces, unfinished attics,
uninsulated or poorly insulated ceilings, porches, and garages.

In turbulent air, like near ceiling fans, heat vents, air conditioners, fresh air
returns, or open windows. Blowing air may prevent CO from reaching the
sensors.

In direct sunlight.

GARAGE

SUGGESTED AREAS FOR INSTALLING ADDITIONAL CO ALARMS

BEDROOM

BEDROOM

HALL

LIVING ROOM

KITCHEN

BASEMENT

BEDROOM

REQUIRED TO MEET NFPA RECOMMENDATIONS

NOTE: Steps 1 through 3 need to be completed within two minutes.
If more than two minutes pass, the Green power LED will stop blinking.
Simply open the battery drawer of the second Alarm and repeat steps 1
through 3.

1. Insert the batteries into the battery

drawer of the next Alarm.
DO NOT CLOSE THE DRAWER.

2. Press and hold the test button

and then close the battery drawer.

3. Once you hear the unit chirp,

release the test button.
The Green power LED will start
to blink indicating the ONELINK

®

Alarm is waiting for program data
from one of the other setup ONELINK

®

Alarms.

4. Press and hold the test button on the first Alarm, until the second Alarm

chirps and its Green power LED stops blinking. Then release the test button.

5. If you have purchased the hardwired battery back-up ONELINK

®

Alarm,

you can now connect the hardwired Alarm by installing the three-wire
connector on the ceiling to the Alarm.

6. Repeat steps 1-5 for additional ONELINK

®

Alarms.

You have now successfully linked your new ONELINK

®

Alarms.

To add additional Alarms at a later time, follow steps 1 through 5.

This CO Alarm is designed for use inside a single-family home or
apartment. It is not meant to be used in common lobbies, hallways,
or basements of multi-family buildings unless working CO Alarms
are also installed in each family living unit. CO Alarms in common
areas may not be heard from inside individual family living units.

This CO Alarm alone is not a suitable substitute for complete
detection systems in places which house many people, like hotels
or dormitories, unless a CO Alarm is also placed in each unit.

• DO NOT use this CO Alarm in warehouses, industrial or commercial

buildings, special-purpose non-residential buildings, RVs, boats,
or airplanes. This CO Alarm is specifically designed for residential
use, and may not provide adequate protection in non-residential
applications.

HOW TO INSTALL THIS ALARM

For quick installation instructions see the “Quick Installation Instructions”
included.

This CO Alarm was designed to be mounted on the ceiling or wall. It is
not a tabletop device.
You must install this device on the ceiling or wall as
outlined below. Read “Where To Install CO Alarms” before starting.

Tools you will need: pencil, drill with 3/16” (5mm) drill bit,
Phillips screwdriver, hammer.

1. Hold the mounting bracket against the ceiling (or wall) so the vertical

mounting slot is aligned in the 12 o’clock position and trace around the
inside of the mounting slots (vertical and horizontal mounting).

2. Put the unit where it won’t get covered with dust when you drill the

mounting holes.

3. Using a 3/16” (5 mm) drill bit, drill a hole through the center of the oval

outlines you traced.

4. Insert the plastic screw anchors (in the plastic bag with screws) into the

holes. Tap the screw anchors gently with a hammer, if necessary, until
they are flush with the ceiling or wall.

5. Line the mounting bracket up over the plastic screw anchors.

6. Screw the mounting bracket to the ceiling or wall through the mounting

slots using the two screws provided.

7. Attach the CO Alarm to the mounting

bracket. Line up the guides on the alarm’s
base with the guides on the mounting
bracket. When guides are lined up, turn
the base clockwise (right) until it snaps
into place.

NOTE: Once the Alarm is snapped onto
the mounting bracket, you can rotate
the Alarm to adjust the alignment.

8. Test the CO Alarm. See “Weekly Testing”

for details.

PARTS OF THIS CO ALARM

1

Test/Silence Button

2

Battery Compartment

3

Power LED

4

CO Alarm LED

WHAT YOU WILL SEE AND HEAR WITH THIS ALARM

Under Normal Operations

Voice: Silent
Horn: Silent
Power LED: Flashes Green once/minute

When You Test the Alarm

Voice: “Testing.” Horn: 4 fast beeps, pause, 4 fast beeps;
Voice: “Warning, evacuate carbon monoxide in [Location, example:

“Basement”]. Evacuate.” Pause. “Highest carbon monoxide level
was [CO level example: _0_ ppm]”.

CO LED: Flashes Red in sync with the horn pattern

If Battery Becomes Low or is Missing

Voice: “Replace battery in [Location, example “Basement”].”

Repeated every 5 hours

Horn: chirps once a minute
Power LED: Flashes Green On for 2 seconds/Off for 2 seconds.

Low Battery Latch is now engaged.

If Alarm is Not Operating Properly (MALFUNCTION SIGNAL)

Voice:

“Detector error in [Location, example “Basement”], please see
manual.” Repeated every 5 hours

Horn: 3 chirps every minute
CO LED: 3 Flashes approximately once a minute

Alarm has reached its End of Life

Voice:

“Detector error in [Location, example “Basement”], please see
manual.” Repeated every 5 hours

Horn: 5 chirps every minute
CO LED: 5 Flashes approximately once a minute

Alarm Levels of CO are Detected

Horn: 4 fast beeps, pause, 4 fast beeps, pause*
Voice:
“Warning, evacuate carbon monoxide in [Location, example:

“Basement”]. Evacuate.” Pause. “Highest carbon monoxide level
was [CO level example: ___ ppm]”.

Horn: 4 beeps, pause, 4 beeps, pause repeating 2 times followed by

Voice Warning above.

CO LED: During Alarm: Flashes Red in sync with the horn pattern.

After Alarm: Flashes Red On for 2 seconds/Off for 2 seconds.
CO Alarm Latch is now engaged.

*NOTE: If unit goes into CO alarm, the regular 4 beeps-brief pause cycle will
repeat for fifteen minutes. After fifteen minutes, the pause will increase to one
minute.

CO Alarm is Silenced

Horn:

Off

CO LED: Flashes Red

STEP BY STEP GUIDE TO PROGRAMMING
THIS ALARM

FOR FIRST TIME AND WHEN CHANGING BATTERIES

Action:

1. Insert batteries (2, AA batteries).

Alarm Will Say:

“Welcome, First Alert Carbon
Monoxide Alarm.”
“No location programmed” if first
time
or “[Location, example:
“Basement”] location programmed”
when changing batteries.
“To select location, press and hold
test button now.”

2. Press & Hold Test Button if you

would like to program the location
or change the location of the
Alarm. Release button after Alarm
responds.

“To save location, press and hold
test button after location is heard.”
Alarm will speak list of locations
(see below).

3. After you hear the location of

where you are placing the Alarm,
Press & Hold the Test Button.

“[Location, example: “Basement”]
location saved.”
If no location is chosen:
“No location saved.”

Your Alarm has now been programmed for the location of your choice.
Available locations:

Basement

Kitchen

Child’s Bedroom

Living Room

Dining Room

Master Bedroom

Family Room

No Location

Guest Bedroom

Office

Hallway

Utility Room

TO LOCK THE BATTERY COMPARTMENT

Do not lock the battery compartment until you install the batteries and
test the CO Alarm.

If the unit does not alarm during testing,
DO NOT lock the battery compartment!
Install new batteries and test again.
If the CO Alarm still does not alarm, replace
it immediately.

1. Using needle-nose pliers, detach one

locking pin from the mounting bracket.

2. After batteries are inserted, then push

the locking pin through the hole near the
battery door latch on the back of the CO
Alarm.

OPTIONAL LOCKING FEATURES

TO LOCK THE MOUNTING BRACKET

1. Using needle-nose pliers, detach one

locking pin from the mounting bracket.

2. Insert the locking pin through the hole on

the back of the CO Alarm as shown in the
diagram.

3. When you attach the CO Alarm to the

mounting bracket, the locking pin’s head
will fit into a notch on the bracket.

The optional locking features are designed to prevent unauthorized removal of the battery or alarm. It is not necessary to activate the locks in
single-family households where unauthorized battery or alarm removal is not a concern.

These CO Alarms have two separate locking features: one to lock the battery compartment, and the other to lock the CO Alarm
to the mounting bracket. You can choose to use either feature independently, or use them both.

Tools you will need: • Needle-nose pliers • Standard flathead screwdriver.

Both locking features use locking pins, which are molded into the mounting bracket. Depending on which locking features you
use, remove one or both pins from the mounting bracket using needle-nose pliers.

To permanently remove either locking pin, insert a flathead screwdriver between the locking pin and the lock, and pry
the pin out of the lock.

TO UNLOCK THE BATTERY COMPARTMENT

1. Remove the CO Alarm from the

mounting bracket. If the unit is locked
to the bracket, see the section
“To Unlock the Mounting Bracket.”

2. Insert a flathead screwdriver under the

head of the locking pin, and gently pry
it out of the battery compartment lock.
(If you plan to relock the battery
compartment, save the locking pin.)

3. To relock the battery compartment,

close the battery door and reinsert
locking pin in lock.

4. Reattach the CO Alarm to the mounting

bracket.

When replacing the batteries, always test
the Alarm before relocking the battery
compartment.

TO UNLOCK THE MOUNTING BRACKET

1. Insert a flathead screwdriver into the

rectangular cut-out on the mounting
bracket nearest to the locking pin.

2. Pry the CO Alarm away from the

bracket by pushing up on the screw-
driver and turning the CO Alarm
counterclockwise (left) at the same
time.

First Alert

®

is a registered trademark of the First Alert Trust used under license.

ONELINK

®

is a trademark of BRK Brands, Inc.

TROUBLESHOOTING GUIDE

If the Alarm...

Problem...

You should...

Horn "chirps" about once per minute.

Low battery warning.

Install two new AA batteries*.

Horn sounds three "chirps" every minute;
LED has 3 flashes with "chirps".

MALFUNCTION SIGNAL. Device is not working
properly, and needs to be replaced.

Units under warranty should be returned to
manufacturer for replacement. See “Limited
Warranty” for details.

The Alarms are linked but do not communicate with
each other.

Possible interference. Reference the Wireless
Operation section of this manual.

Move Alarms to different locations. Add an additional
Alarm between the unresponsive Alarms to route the
signal around obstructions.

CO Alarm goes back into alarm 4 minutes after you
Silence it.

CO levels indicate a potentially dangerous
situation.

IF YOU ARE FEELING SYMPTOMS OF CO
POISONING, EVACUATE your home and call 911
or the Fire Department. Refer to "If The CO Alarm
Sounds" for details.

CO Alarm sounds frequently even though no high
levels of CO are revealed in an investigation.

The CO Alarm may be improperly located. Refer to
“Where to Install CO Alarms” for details.

Relocate your Alarm. If frequent alarms continue,
have home rechecked for potential CO problems.
You may be experiencing an intermittent CO problem.

*For a list of acceptable replacement batteries, see “Regular Maintenance.”

If you have questions that cannot be answered by reading this manual, call Consumer Affairs at 1-800-323-9005, M-F 7:30 a.m. to 5:00 p.m. (CST)

The light flashes (RED) and the horn sounds 5
“chirps” every minute;
Voice: "Detector error in [Location, example
"Basement"], please see manual" repeated every 5
hours.

END OF LIFE SIGNAL. CO Alarm needs to be
replaced.

Immediately replace the CO Alarm.

BRK Brands, Inc., ("BRK") the maker of First Alert

®

brand products warrants

that for a period of seven years from the date of purchase, this product will
be free from defects in material and workmanship. BRK, at its option, will
repair or replace this product or any component of the product found to be
defective during the warranty period. Replacement will be made with a new or
remanufactured product or component. If the product is no longer available,
replacement may be made with a similar product of equal or greater value.
This is your exclusive warranty.

This warranty is valid for the original retail purchaser from the date of initial
retail purchase and is not transferable. Keep the original sales receipt. Proof
of purchase is required to obtain warranty performance. BRK dealers, service
centers, or retail stores selling BRK products do not have the right to alter,
modify or any way change the terms and conditions of this warranty.

This warranty does not cover normal wear of parts or damage resulting from
any of the following: negligent use or misuse of the product, use on improper
voltage or current, use contrary to the operating instructions, disassembly,
repair or alteration by anyone other than BRK or an authorized service center.
Further, the warranty does not cover Acts of God, such as fire, flood,
hurricanes and tornadoes or any batteries that are included with this unit.

BRK shall not be liable for any incidental or consequential damages caused
by the breach of any express or implied warranty. Except to the extent
prohibited by applicable law, any implied warranty of merchantability or fitness
for a particular purpose is limited in duration to the duration of the above
warranty. Some states, provinces or jurisdictions do not allow the exclusion or
limitation of incidental or consequential damages or limitations on how long
an implied warranty lasts, so the above limitations or exclusion may not apply
to you. This warranty gives you specific legal rights, and you may also have
other rights that vary from state to state or province to province.

How to Obtain Warranty Service
Service:
If service is required, do not return the product to your retailer.
In order to obtain warranty service, contact the Consumer Affairs Division at
1-800-323-9005, 7:30 AM - 5:00 PM Central Standard Time, Monday through
Friday. To assist us in serving you, please have the model number and date of
purchase available when calling. For Warranty Service return to:
BRK Brands, Inc., 25 Spur Drive, El Paso, TX 79906

Battery: BRK Brands, Inc. make no warranty, express or implied, written or
oral, including that of merchantability or fitness for any particular purpose
with respect to battery.

LIMITED WARRANTY

REGULATORY INFORMATION FOR CO ALARMS, Continued

Standards: Underwriters Laboratories Inc. Single and Multiple Station carbon
monoxide alarms UL2034.

According to Underwriters Laboratories Inc. UL2034, Section 1-1.2: “Carbon
monoxide alarms covered by these requirements are intended to respond to
the presence of carbon monoxide from sources such as, but not limited to,
exhaust from internal-combustion engines, abnormal operation of fuel-fired
appliances, and fireplaces. CO Alarms are intended to alarm at carbon
monoxide levels below those that could cause a loss of ability to react to the
dangers of Carbon Monoxide exposure.” This CO Alarm monitors the air at
the Alarm, and is designed to alarm before CO levels become life threatening.
This allows you precious time to leave the house and correct the problem.
This is only possible if Alarms are located, installed, and maintained as
described in this manual.

Gas Detection at Typical Temperature and Humidity Ranges: The CO
Alarm is not formulated to detect CO levels below 30 ppm typically. UL tested
for false alarm resistance to Methane (500 ppm), Butane (300 ppm), Heptane
(500 ppm), Ethyl Acetate (200 ppm), Isopropyl Alcohol (200 ppm) and Carbon
Dioxide (5000 ppm). Values measure gas and vapor concentrations in parts
per million.

Audible Alarm: 85 dB minimum at 10 feet (3 meters).

GENERAL LIMITATIONS OF CO ALARMS

This CO Alarm is intended for residential use. It is not intended for use
in industrial applications where Occupational Safety and Health
Administration (OSHA) requirements for carbon monoxide detectors
must be met.

CO alarms may not waken all individuals. If children or others do not readily
waken to the sound of the CO alarm, or if there are infants or family members
with mobility limitations, make sure that someone is assigned to assist them
in the event of an emergency.

CO Alarms will not work without power. This alarm requires a two (2) AA
batteries to operate.

CO Alarms for Solar or Wind Energy users and battery backup power
systems:
AC powered CO Alarms should only be operated with true or pure
sine wave inverters. Operating this Alarm with most battery-powered UPS
(uninterruptible power supply) products or square wave or “quasi sine wave”
inverters will damage the Alarm. If you are not sure about your inverter or
UPS type, please consult with the manufacturer to verify.

This CO Alarm will not sense carbon monoxide that does not reach the
sensor.

This CO Alarm will only sense CO at the sensor. CO may be present

in other areas. Doors or other obstructions may affect the rate at which CO
reaches the CO Alarm. For this reason, if bedroom doors are usually closed
at night, we recommend you install a CO Alarm in each bedroom and in the
hallway between them.

CO Alarms may not sense CO on another level of the home. For example,
a CO Alarm on the second level, near the bedrooms, may not sense CO in the
basement. For this reason, one CO Alarm may not give adequate warning.
Complete coverage is recommended. Place CO Alarms on each level of the
home.

CO Alarms may not be heard. The alarm horn loudness meets or exceeds
current UL standards of 85 dB at 10 feet (3 meters). However, if the CO Alarm
is installed outside the bedroom, it may not wake up a sound sleeper or one
who has recently used drugs or has been drinking alcoholic beverages. This
is especially true if the door is closed or only partly open. Even persons who
are awake may not hear the alarm horn if the sound is blocked by distance or
closed doors. Noise from traffic, stereo, radio, television, air conditioner, or
other appliances may also prevent alert persons from hearing the alarm horn.
This CO Alarm is not intended for people who are hearing impaired.

CO Alarms are not a substitute for a smoke alarm. Although fire is a
source of carbon monoxide, this CO Alarm does not sense smoke or fire. This
CO Alarm senses CO that may be escaping unnoticed from malfunctioning
furnaces, appliances, or other sources. Early warning of fire requires the
installation of smoke alarms.

CO Alarms are not a substitute for life insurance. Though these CO Alarms
warn against increasing CO levels, BRK Brands, Inc. does not warrant or
imply in any way that they will protect lives from CO poisoning. Homeowners
and renters must still insure their lives.

CO Alarms have a limited life. Although the CO Alarm and all of its parts
have passed many stringent tests and are designed to be as reliable as
possible, any of these parts could fail at any time. Therefore, you must test
your CO Alarm weekly.

CO Alarms are not foolproof. Like all other electronic devices, CO Alarms
have limitations. They can only detect CO that reaches their sensors. They
may not give early warning to rising CO levels if the CO is coming from a
remote part of the home, away from the CO Alarm.

REGULATORY INFORMATION FOR CO ALARMS

UNDERWRITERS LABORATORIES INC. UL2034

WHAT LEVELS OF CO CAUSE AN ALARM?
Underwriters Laboratories Inc. Standard UL2034 requires residential CO
Alarms to sound when exposed to levels of CO and exposure times as
described below. They are measured in parts per million (ppm) of CO over
time (in minutes).

UL2034 Required Alarm Points*:

If the alarm is exposed to 400 ppm of CO, IT MUST ALARM BETWEEN
4 and 15 MINUTES.

If the alarm is exposed to 150 ppm of CO, IT MUST ALARM BETWEEN
10 and 50 MINUTES.

If the alarm is exposed to 70 ppm of CO, IT MUST ALARM BETWEEN
60 and 240 MINUTES.

* Approximately 10% COHb exposure at levels of 10% to 95% Relative
Humidity (RH).
The unit is designed not to alarm when exposed to a constant level of
30 ppm for 30 days.

CO Alarms are designed to alarm before there is an immediate life threat.
Since you cannot see or smell CO, never assume it’s not present.

An exposure to 100 ppm of CO for 20 minutes may not affect average,
healthy adults, but after 4 hours the same level may cause headaches.

An exposure to 400 ppm of CO may cause headaches in average, healthy
adults after 35 minutes, but can cause death after 2 hours.

This CO Alarm measures exposure to CO over time. It alarms if CO levels
are extremely high in a short period of time, or if CO levels reach a certain
minimum over a long period of time. The CO Alarm generally sounds an
alarm before the onset of symptoms in average, healthy adults.

Why is this important? Because you need to be warned of a potential CO
problem while you can still react in time. In many reported cases of CO
exposure, victims may be aware that they are not feeling well, but become
disoriented and can no longer react well enough to exit the building or get
help. Also, young children and pets may be the first affected. The average
healthy adult might not feel any symptoms when the CO Alarm sounds.
However, people with cardiac or respiratory problems, infants, unborn babies,
pregnant mothers, or elderly people can be more quickly and severely affected
by CO. If you experience even mild symptoms of CO poisoning, consult your
doctor immediately!

HOW CAN I PROTECT MY FAMILY FROM
CO POISONING?

A CO Alarm is an excellent means of protection. It monitors the air and sounds
a loud alarm before Carbon Monoxide levels become threatening for average,
healthy adults.
A CO Alarm is not a substitute for proper maintenance of home
appliances.
To help prevent CO problems and reduce the risk of CO poisoning:

• Clean chimneys and flues yearly. Keep them free of debris, leaves, and

nests for proper air flow. Also, have a professional check for rust and
corrosion, cracks, or separations. These conditions can prevent proper
air movement and cause backdrafting. Never “cap” or cover a chimney
in any way that would block air flow.

• Test and maintain all fuel-burning equipment annually. Many local gas

or oil companies and HVAC companies offer appliance inspections for
a nominal fee.

• Make regular visual inspections of all fuel-burning appliances. Check

appliances for excessive rust and scaling. Also check the flame on the
burner and pilot lights. The flame should be blue. A yellow flame means
fuel is not being burned completely and CO may be present. Keep the
blower door on the furnace closed. Use vents or fans when they are
available on all fuel-burning appliances. Make sure appliances are
vented to the outside. Do not grill or barbecue indoors, or in garages
or on screen porches.

• Check for exhaust backflow from CO sources. Check the draft hood on

an operating furnace for a backdraft. Look for cracks on furnace heat
exchangers.

• Check the house or garage on the other side of shared wall.
• Keep windows and doors open slightly. If you suspect that CO is

escaping into your home, open a window or a door. Opening windows
and doors can significantly decrease CO levels.

In addition, familiarize yourself with all enclosed materials. Read this
manual in its entirety, and make sure you understand what to do if your
CO Alarm sounds.

WHAT YOU NEED TO KNOW ABOUT CO

WHAT IS CO?

CO is an invisible, odorless, tasteless gas produced when fossil fuels do not
burn completely, or are exposed to heat (usually fire). Electrical appliances
typically do not produce CO.

These fuels include: Wood, coal, charcoal, oil, natural gas, gasoline,
kerosene, and propane.

Common appliances are often sources of CO. If they are not properly main-
tained, are improperly ventilated, or malfunction, CO levels can rise quickly.
CO is a real danger now that homes are more energy efficient. “Air-tight”
homes with added insulation, sealed windows, and other weatherproofing
can “trap” CO inside.

SYMPTOMS OF CO POISONING

These symptoms are related to CO POISONING and should be discussed
with ALL household members.

Mild Exposure: Slight headache, nausea, vomiting, fatigue (“flu-like”
symptoms).

Medium Exposure: Throbbing headache, drowsiness, confusion, fast heart
rate.

Extreme Exposure: Convulsions, unconsciousness, heart and lung failure.
Exposure to Carbon Monoxide can cause brain damage, death.

Some individuals are more sensitive to CO than others, including people
with cardiac or respiratory problems, infants, unborn babies, pregnant
mothers, or elderly people can be more quickly and severely affected by
CO. Members of sensitive populations should consult their doctors for
advice on taking additional precautions.

FINDING THE SOURCE OF CO AFTER AN ALARM

Carbon monoxide is an odorless, invisible gas, which often makes it difficult
to locate the source of CO after an alarm. These are a few of the factors that
can make it difficult to locate sources of CO:

House well ventilated before the investigator arrives.

Problem caused by “backdrafting.”

Transient CO problem caused by special circumstances.

Because CO may dissipate by the time an investigator arrives, it may be
difficult to locate the source of CO. BRK Brands, Inc. shall not be obligated
to pay for any carbon monoxide investigation or service call.

POTENTIAL SOURCES OF CO IN THE HOME

Fuel-burning appliances like: portable heater, gas or wood burning fireplace,
gas kitchen range or cooktop, gas clothes dryer.

Damaged or insufficient venting: corroded or disconnected water heater
vent pipe, leaking chimney pipe or flue, or cracked heat exchanger, blocked
or clogged chimney opening.

Improper use of appliance/ device: operating a barbecue grill or vehicle in
an enclosed area (like a garage or screened porch).

Transient CO Problems: “transient” or on-again-off-again CO problems can
be caused by outdoor conditions and other special circumstances.

The following conditions can result in transient CO situations:

1. Excessive spillage or reverse venting of fuel appliances caused by outdoor

conditions such as:

• Wind direction and/or velocity, including high, gusty winds. Heavy air in

the vent pipes (cold/humid air with extended periods between cycles).

• Negative pressure differential resulting from the use of exhaust fans.

• Several appliances running at the same time competing for limited

fresh air.

• Vent pipe connections vibrating loose from clothes dryers, furnaces,

or water heaters.

• Obstructions in or unconventional vent pipe designs which can amplify

the above situations.

2. Extended operation of unvented fuel burning devices (range, oven,

fireplace).

3. Temperature inversions, which can trap exhaust close to the ground.

4. Car idling in an open or closed attached garage, or near a home.

These conditions are dangerous because they can trap exhaust in your home.
Since these conditions can come and go, they are also hard to recreate during
a CO investigation.

ADDING AND LINKING ADDITIONAL ONELINK

®

ALARMS

IF YOUR CO ALARM SOUNDS

Actuation of your CO Alarm indicates the presence of carbon monoxide
(CO) which can kill you. In other words, when your CO Alarm sounds,
you must not ignore it!

IF THE ALARM SIGNAL SOUNDS

1. Operate the Test/Silence button.

2. Call your emergency services, fire department or 911. Write down the

number of your local emergency service here:

________________________________________________________________

3. Immediately move to fresh air—outdoors or by an open door or window.

Do a head count to check that all persons are accounted for. Do not re-
enter the premises, or move away from the open door or window until
the emergency services responder has arrived, the premises have been
aired out, and your CO Alarm remains in its normal condition.

4. After following steps 1-3, if your CO Alarm reactivates within a 24-hour

period, repeat steps 1-3 and call a qualified appliance technician to inves-
tigate for sources of CO from fuel-burning equipment and appliances, and
inspect for proper operation of this equipment. If problems are identified
during this inspection have the equipment serviced immediately. Note
any combustion equipment not inspected by the technician, and consult
the manufacturers’ instructions, or contact the manufacturers directly,
for more information about CO safety and this equipment. Make sure
that motor vehicles are not, and have not, been operating in an attached
garage or adjacent to the residence. Write down the number of a qualified
appliance technician here:

________________________________________________________________

Alarms have various limitations. See "General Limitations of CO Alarms"
for details.

“ALARM—MOVE TO FRESH AIR”

If you hear the CO alarm horn and the CO red light is flashing,

move everyone to a source of fresh air.

DO NOT remove the batteries!

USING THE SILENCE FEATURES

Never remove the batteries to quiet an unwanted alarm. Removing the
batteries disables the alarm and removes your protection.

The Silence Feature is intended to temporarily silence the horn while you
identify and correct the problem. Do not use the Silence Feature in emergency
situations. It will not correct a CO problem.

The Silence Feature can temporarily quiet an unwanted alarm for several
minutes. You can silence this Alarm by pressing the Test/Silence button on
the alarm cover for at least 3-5 seconds.

After the Test/Silence button is released, the Red LED blinks during the silence
mode.

When the CO Alarm is Silenced the CO Alarm will remain silent for up to
4 minutes. After 4 minutes, if CO levels remain potentially dangerous the horn
will start sounding again.

SILENCING THE LOW BATTERY WARNING

This silence feature can temporarily quiet the low battery warning “chirp” for
up to 8 hours. You can silence the low battery warning “chirp” by pressing
the Test/Silence button on the alarm cover.

Once the low battery warning “chirp” silence feature is activated, the unit
continues to flash the Green light twice a minute for 8 hours. After 8 hours, the
low battery “chirp” will resume. Replace the batteries as soon as possible;
this unit will not operate without battery power!

To deactivate this feature:

Press the Test/Silence button again. The unit will

go into Test Mode and the low battery warning will resume (LED flashes and
unit sounds “chirp” once a minute).

SILENCING THE END OF LIFE SIGNAL

This silence feature can temporarily quiet the End of Life warning “chirp” for
up to 2 days. You can silence the End of Life warning “chirp” by pressing the
Test/Silence button. The horn will chirp, acknowledging that the End of Life
silence feature has been activated.

After approximately 2 days, the End of Life “chirp” will resume.
After approximately 2-3 weeks the End of Life warning cannot be silenced.

LATCHING FEATURES

Alarm Latch is activated after an Alarm is exposed to alarm levels of carbon
monoxide. After CO levels drop below alarm levels, the “CO” Red LED will
begin to flash On for 2 seconds/Off for 2 seconds. It will continue to flash or
“latch” for about 15 minutes, to give you time to determine which unit initiated
the alarm.

Low Battery Latch is activated when the Alarm is in the "low battery
condition". When this occurs, the Power LED flashes Green On for 2 seconds/
Off for 2 seconds for about 15 minutes. This feature is designed to help you
identify which Alarm needs to have the battery replaced. Although, the Alarm
will sound the low battery chirp approximately once every minute, sometimes
during the initial stages of "low battery", the Alarm will chirp in greater intervals
than one minute, sometimes up to several hours, until the battery reaches a
steady low battery level. This innovative feature eliminates the frustration of
waiting for and/or identifying which unit is chirping.

WEEKLY TESTING

Test the CO Alarm once a week. If the CO Alarm ever fails to test
properly, have it replaced immediately! If the CO Alarm is not
working properly, it cannot alert you to a problem.

DO NOT stand close to the Alarm when the horn is sounding.
Exposure at close range may be harmful to your hearing.
When testing, step away when horn starts sounding.

It is important to test this unit every week to make sure it is working
properly. Using the test button is the recommended way to test this CO
Alarm.

You can test this CO Alarm by

pressing and holding the Test/Silence button

on the Alarm cover (typically 3-5 seconds).

During testing, you will see and hear the following sequence:

• The Horn will sound 4 beeps, pause, 4 beeps. The Power LED will be

Off and the CO LED flashes Red.

If the unit does not alarm, make sure the batteries are correctly installed, and
test again. If the unit still does not alarm, replace it immediately.

REGULAR MAINTENANCE

This unit has been designed to be as maintenance-free as possible, but there
are a few simple things you must do to keep it working properly.

Use only the replacement batteries listed below. The unit may not
operate properly with other batteries. Never use rechargeable batteries
since they may not provide a constant charge.

Test it at least once a week.

Clean the CO Alarm at least once a month; gently vacuum the outside
of the CO Alarm using your household vacuum’s soft brush attachment.
A can of clean compressed air (sold at computer or office supply stores)
may also be used. Follow manufacturer instructions for use. Test the CO
Alarm. Never use water, cleaners or solvents since they may damage the
unit.

If the CO Alarm becomes contaminated by excessive dirt, dust and/or
grime, and cannot be cleaned to avoid unwanted alarms, replace the unit
immediately.

Relocate the unit if it sounds frequent unwanted alarms. See “Where CO
Alarms Should Not Be Installed” for details.

Choosing a replacement battery:
Your CO Alarm requires two standard AA batteries. The following batteries are
acceptable as replacements: Energizer E91. These batteries are available at
many local retail stores.

Actual battery service life depends on the CO Alarm and the environment in
which it is installed. All the batteries specified above are acceptable replace-
ment batteries for this unit. Regardless of the manufacturer’s suggested
battery life, you MUST replace the battery immediately once the unit starts
“chirping” (the “low battery warning”).

To replace the batteries (without removing Alarm from the ceiling or wall):

1. Open the battery compartment.

2. Press tabs A and B as shown in the

diagram and remove each battery.

3. Insert the new batteries, making sure

they snap completely into the battery
compartment. Match the terminals on
the ends of the batteries with the
terminals on the unit.

4. Close the battery compartment, and

then test the unit by pressing the
Test/Silence button.

AB

What You See and Hear

Refer to section “What You Will See and Hear With This Alarm”.

LISTED TO

UL 2034

STANDARD

For your records, please record:

Date Purchased: _______________________________

Where Purchased: ____________________________________________

Date Installed: ____________/____________Month/Year

Replace alarm 7 years after installation. Please write the date in the
space provided:

_____________/____________Month/Year

The alarm will also provide an audible End-of-Life Signal approximately
7 years after installation to remind you to replace the unit.

The End-of-Life Signal can be silenced for up to 2 days. Do not unplug
the alarm or remove the batteries until you get replacement.