ALR: Set alarms

$CRALR,hhmmss.ss,xxx,A,A,c--c*hh<CR><LF>
| | | | | |
| | | | | +----------------- 6
| | | | +----------------- 5
| | | +-------------------- 4
| | +---------------------- 3
| +------------------------- 2
+--------------------------------- 1

1. Time of alarm condition change, UTC
2. Local alarm number(identifier) (SEE NOTE.)
3. Alarm condition(A=threshold exceeded, V=not exceeded)
4. Alarm's acknowledge state, A=acknowledged V=unacknowledged
5. Alarm's description text
6. Checksum


NOTE Local alarm number (identifier):
001 = “NAVTEX: Navigational warning”
002 = “NAVTEX: Meteorological warning”
003 = “NAVTEX: Search and rescue information”
006 = “NAVTEX: General failure”
051 = “NAVTEX: Printer Error”
052 = “NAVTEX: Battery Error”