FUJITSU MAS3367 User Manual

Page 196

Advertising
background image

Parameter Data Formats

4 - 20

C141-E167

Bit
Byte

7

6

5

4

3

2

1

0

0

0

0

0

0

0

1

1

1

1

X‘0A’ (Page Length)

2

(Reserved)

EER

PER

DTE

DCR

Default

0

0

0

0

1

0

0

0

Variable

0

0

0

0

1

1

1

1

3

Number of retries during VERIFY.

Default

X‘3F’

Variable

X‘FF’

4

Correctable Bit Length

Default

X‘E9’ (=233 bits)

Variable

X‘00’

5-9

X‘0000000000’ (Reserved)

10-11

Recovery Time Limit

Default

X‘7530’

Variable

X‘FFFF’

Figure 4.5

MODE SELECT parameters: verify error recovery parameters

The error recovery parameters divided in this page descriptor are applicable for the following
commands.

VERIFY

WRITE AND VERIFY (verify operation)

Note:

If selecting the SCSI-1/CCS mode in the CHANGE DEFINITION command specification, use
Page code = 1 (Read/Write Error Recovery Parameters) instead of this parameter.

a.

Error recovery flags

EER (enable early recovery)

PER (post error)

DTE (disable transfer on error)

DCR (disable correction)

The definitions and functions of these control flags are the same as for the read/write error
recovery parameters. See item (1) concerning the details.

(See the
Note.)