caution!: Do not switch system to cool if the outdoor temperature is below 50°F (10°C). This can damage the

air conditioning system and may cause personal injury.

Action: Set the Mode switch to Cool. Press the button until the temperature setting is 3°F below the room

temperature.

Result: The A/C system and fan should turn on.

Action: Set the Mode switch to Off.

Result: The A/C should turn off (there may be a fan delay).

Action: Set the Mode switch to Heat. Press the button until the temperature setting is 3°F above the room

temperature.

Result: The heating systems and fan should turn on (there may be a time delay depending on your system).

Action: Set the Mode switch to Off.

Result: The heating system should turn off (there may be a fan delay).

Action: Set the Fan switch to On (continuous indoor fan operation).

Result: The blower fan should turn on.

Action: Set the Fan switch to Auto.

Result: The blower fan should turn off.

If the above test was successful, you have a proper installation.
If not:

Double check that wires are securely connected and are connected to the proper terminals. Consult the

troubleshooting section (see Page 10).