Shutdown & Cleaning - After Direct Immersion Method Applications

24

312079A

Shutdown & Cleaning - After Direct Immersion Method
Applications

Pail Flushing

1. Relieve pressure, page 7.

2. If you used a spray gun, remove tip and guard

assembly from gun and place in flushing fluid.

If you used a roller, leave roller assembly
attached to gun.

3. Lift suction tube and prime tube from paint pail.

Let them drain into paint for a while.

4. Separate prime tube

(smaller) from suction tube
(larger).

5. Place waste and

paint pail side by
side.

6. Submerge suction tube

in water or flushing
solvent.

7. Place prime tube in waste

pail.

8. Set AllControl to

PRIME/CLEAN PUMP.

9. Flush until approximately 1/3 of the flushing

fluid is emptied from the pail.

10. Turn AllControl to OFF.

11.

a. If you used a spray

gun only, continue
Pail Flushing, Step 12.

b. If you used a roller follow Cleaning Roller

instructions beginning on page 28.

For short term shutdown periods (over-
night to one week) refer to Short Term
Storage, page 29.

For flushing after spraying oil-based coat-
ings, use compatible oil-based flushing
fluid or mineral spirits.

For flushing after spraying water-based
coatings, use water.

If you are using water-based materials, you
have the option of following the cleanup
procedure described below, or for faster
cleanup, Power Flush, starting on page 26.