Troubleshooting Guide

The following procedures must be performed by a qualified service technician.

Problem

Possible Cause

Solution

The machine does not cool, or cools
only partially, but the compressors
are running

The machine does not cool or cools
only partially, but one or more of the
compressors are not running

The machine over-freezes, making
the auger movement slow or
stopped

The machine is noisy

The main power switch is “On”. The
unit is not running.

Product is leaking out of the bowl

• Allow at least 8” (20cm) between the

machine and anything next to it; keep
away from heat sources

• Return to freeze mode
• Remove the side panels. Using a

brush or compressed air clean the
condenser

• Check the fan motor’s electrical

connections and, if disconnected,
reconnect. If still not operating,
replace the motor

• Locate the leak, eliminate it and

recharge the system

• Replace the malfunctioning

components

• Check the contacts and correct those

that are incomplete

• Replace the compressor(s)

• Check the electrical connections to

the PC board as well as the
transformer feeding the PC board
and correct

• Check the product brix and correct
• Reset the screw toward the “-”

position to produce a thinner
consistency product

• Using pliers, straighten the limit switch

arm

• Add more product or turn the

refrigeration “Off”

• Replace the PC board

• Check and correct

• Replace the fuse(s)
• Clean the condenser or add

ventilation space around the machine
(the cutout switch reset is automatic
when the conditions are corrected)

• Check the contacts and correct those

that are incomplete

• Replace the switch

• Replace or reposition the seals

• The space around the machine is

inadequate for ventilation

• Freezer is in defrost
• The condenser fins are clogged with

airborne particles

• Fan motor is not running

• Refrigerant is leaking

• Electrical components of the

compressor(s) are not functioning

• Some electrical connections are not

complete

• One or more of the compressors are

malfunctioning

• No current is coming to the “com-

pressor delay” PC board

• The product brix is too low
• The screw setting for the product

consistency control system is set too
far toward the “+” position

• The limit switch arm is bent away

from the gearmotor and prevents
contact

• The level of the product in the bowl is

too low, exposing the auger

• The compressor PC board contacts

don’t open

• The fan motor blades are hitting

internal components

• The fuse(s) are blown
• The pressure cutout switch has

activated

• Some electrical connections are not

complete

• The main power is not functioning

• One of the bowl seals is not in place