GE Profile PT925DN User Manual

Pt925dn, Ge profile, 30" built-in single/double convection wall oven

Advertising
background image

Listed by

Underwriters

Laboratories

For answers to your Monogram,

®

GE Profile

or

GE

®

appliance questions, visit our website at

ge.com or call GE Answer Center

®

service,

800.626.2000.

Specification Revised 4/09

220244

PT925DN

GE Profile

30" Built-In Single/Double Convection Wall Oven

KW Rating

240V

3.9

208V 2.9

Breaker Size

240V

20 Amps

208V 20 Amps

Dimensions and Installation Information (in inches)

Most 30” Wall Cabinets can be used with this unit.
Note:
These ovens are not approved for

stackable installations. Cabinets installed
adjacent to wall ovens must have an adhesion
spec of at least a 194°F temperature rating.
Door handle protrudes 3" from door face. Cabinets
and drawers on adjacent 45° and 90° walls should
be placed to avoid interference with the handle.
Electric wall ovens are not approved for

installation with a plug and receptacle. They

must be hard wired in accordance with

installation instructions.
Installation Information: Before installing, consult
installation instructions packed with product for
current dimensional data.
Side-by-side installations require at least 2"
between cutouts.

CUTOUT

HEIGHT

27 1/4" MIN.

27 5/16" MAX.

CUTOUT

WIDTH

28 1/2" MIN.

28 5/8" MAX.

5"

22" TO

BOTTOM OF

JUNCTION BOX

JUNCTION B

LOCATION

RECOMMENDED

CUTOUT

LOCATION

32 1/2"

FROM THE

FLOOR

CABINET

WIDTH

30"

ALLOW 11/16" FOR

OVERLAP OF THE

OVEN OVER SIDE

EDGES OF CUTOUT

THE OPENING

BETWEEN INSIDE

WALLS MUST

BE AT LEAST

28 1/2"WIDE

ALLOW 1" FOR

OVERLAP

ON OVEN TOP

AND BOTTOM

OF CUTOUT

21"

ALLOW A MINIMUM

F 21" FOR CLEARANCE

ADJACENT CORNERS,

RAWERS, WALLS ETC.

N THE DOOR IS OPENED.

Allow 11/16

(1.75 cm) for

overlap of oven

over side edges

of cutout

Cutout

Width

28 1/2

(72.4 cm)

Min.

28 5/8

(72.7 cm)

Max.

15

(38.1 cm)

Cabinet

Width

30

(76.2 cm)

Allow a minimum

of 15” (38.1 cm) for

clearance to adjacent

corners, drawers,

walls, etc. when

door is open

Allow 1” (2.5 cm)

minimum for

overlap of oven

top and 1 1/4”

(3.2 cm) overlap

of oven bottom

of cutout

Recommended

cutout

location from

floor 26 1/2”

(67.3 cm) max

Opening

Between

Inside Walls

Must Be

At Least

28 1/2”

(72.4 cm)

Wide

Junction Box

Location

(junction box

may be

located in

adjacent

cabinet)

9 1/2

(12.7 cm)

Max.

Cutout

Height

27 1/4

(69.2 cm) Min.

27 5/16

(69.4 cm) Max.

22 (55.9 cm)

Min. to

Bottom of

Junction Box

CL

2 x 4 or

equivalent

runners

Suitable

bracing

to support

runners

21-5/8"

over centerline

of cabinet

(must support 275 lbs.)

Cutout width
28-1/2'' MIN.
28-5/8'' MAX.

29-3/4

C

30

Recommended

cutout location

32-1/2"

from floor

21

Junction

box

location

Allow minimum of 21'' for clearance

to adjacent corners, drawers, walls, or etc.
A=Allow 1" overlap of oven over top and bottom edges of cutout.

B=Allow 11/16"–3/4" for overlap of oven over side edges of cutout.

C=28-1/4" without trim and 28-3/4" with trim.

Conduit

(72"

long)

5

27-1/4'' MIN.
27-5/16'' MAX.
Cutout height

A

B

23-1/2'' MIN.

Cutout depth

22'' MIN.

Advertising
This manual is related to the following products: