Milwaukee EARTHSTOVE 1500HT User Manual

Page 5

Advertising
background image

PLANNING YOUR INSTALLATION

PAGE 5

COMBUSTIBLE WALL CLEARANCE


WARNING: IT IS VERY IMPORTANT THAT YOU

OBSERVE THE MINIMUM CLEARANCES.

There are listed clearances for your stove which were

determined in a Laboratory test using various "classes"

of stove pipe or chimney. Minimums are first estab-

lished for the stove itself and increased based on how

much heat is transferred by each class of pipe.

Note: Manufactured (mobile) home installations require

the use of a Type L Vent Chimney connector only. Use

of a single wall flue pipe connection is not permitted.

Residential Reduced Clearance
Using Listed L Vent pipe (double wall air insulated) to
the top of the stove.
Approved brands are: Jakes-Evans, Dura-Vent, Secu-
rity, Pro-Vent, Ameri-Tek, Metal Bestos.


Clearances (inches / millimeters)
A. 10 ½ / 267

C. 15 / 381

E. 9 ½ / 241

B. 20 / 508

D. 8 / 203

F. 5 / 127


Residential Standard (not approved for manufac-
tured [mobile] homes)

Using single wall pipe connector to the top of the stove.


Clearances (inches / millimeters)
A. 15 / 381

C. 15 / 381

E. 8 ½ / 216

B. 19 / 483

D. 13 / 330

F. 5 / 127


Manufactured (Mobile) Home Standard Clearance

Using Approved L Vent only. Approved brands are
Dura-Vent, Security, Pro-Vent, and Ameri-Tek. Manu-
factured (mobile) Home installations must use a rain
cap with a spark arrestor.


Clearances (inches / millimeters)
A. 10 ½ / 267

C. 15 / 381

E. 9 ½ / 241

B. 20 / 508

D. 8 / 203

F. 5 / 127



CORNER
INSTALLATION







PARALLEL
INSTALLATION

*ALCOVE CLEARANCE
Required pipe: Type L-Vent pipe to top of stove. Ap-
proved brands are Dura-Vent, Pro-Vent, Ameri-I-Tek,
Standex, and Metal Bestos.

Alcoves must have minimum dimensions of 84" (213
cm) height minimum, 46" (117 cm) width minimum and
24" (610 mm) depth maximum.

Alcove Clearances:
Back wall to pipe O.D.

10 1/2" (267 mm) Minimum

Side wall to pipe O.D.

20" (508 mm) Minimum

Back wall to stove

8" (203 mm) Minimum

Side wall to stove

9 1/2" (241 mm) Minimum


* NOTE: Alcove dimensions cannot be reduced by the use of

non-combustible materials such as brick, stone, etc. Alcove
dimensions listed are minimum dimensions and are not
measurements for building an Alcove. You will need to con-
sider these clearances, as well as other dimensional re-
quirements before you build the alcove and install this appli-
ance.


PROTECTED WALL CLEARANCE when the stove is in-
stalled adjacent to a protected wall system. The variance must
be approved by your local building official. Normally, the pro-
tected wall system is defined as a non- combustible material
with a minimum of 1" air space behind. Check your local build-
ing codes or with a qualified installer (Ref. NFPA 211).

OPTIONAL ARCH TREATMENT
An alcove depth of 24" (610 mm) (or less) will allow for a
minimum height of 84" (213 cm) and may be trimmed with a 2
1/4" (57 mm) maximum arch treatment if desired.

Advertising