ultracompact VariO loudspeaker
10 No automatic turn-off voltages. Voltages
above 265 V AC are fuse protected but
may cause permanent damage to the
power supply. Voltages below 90 V AC
may result in intermittent operation.
11 Current draw for a single loudspeaker.
Loop out not used.
AC POWER
AC power connector
PowerCon with looping output
Voltage selection
Automatic
Safety agency rated operating voltage
100 V AC – 240 V AC, 50/60 Hz
Turn on/turn off points
10
90 V AC – 264 V AC, 50/60 Hz
CURRENT DRAW
11
Idle current
0.448 A rms (115 V AC), 0.285 A rms (230 V AC), 0.497 A rms (100 V AC)
Max. long-term continuous current (>10 sec)
2.55 A rms (115 V AC), 1.55 A rms (230 V AC), 2.75 A rms (100 V AC)
Burst current (<1 sec)
2.9 A rms (115 V AC), 1.7 A rms (230 V AC), 3.2 A rms (100 V AC)
Ultimate short-term peak current draw
12.0 A peak (115 V AC), 9.0 A peak (230 V AC), 13.0 A peak (100 V AC)
Inrush current
15.0 A peak (115 V AC), 13.0 A peak (230 V AC), 15.0 A peak (100 V AC)
PHYSICAL
Enclosure
Premium birch plywood
Finish
Black textured
Protective grille
Powder-coated hex-stamped steel
Rigging
QuickFly rigging options
Dimensions
9.00 w x 19.04 h x 10.20 d (228.60 mm x 483.55 mm x 259.08 mm)
Weight
28 lbs (12.70 kg)