When the switch is in the 240 volt (down) position, you can
acess

half of the rated power of the generating set at 120

volts from the GFCI duplex receptacle and up to half of the
rated power of the set at 120 volts from 120V twist-lock
receptacle; or full rated power of the set at 240 volts from
the 240V twist-lock receptacle.

12. Full Power Switch – The generator is provided with a full

power switch. Figures 4C and 4D show simplified wiring
diagrams of the dual voltage system.

When the full power switch is in the 120 volt (up) position,
you can access the

full rated power

of the generator at

120 volts from the GFCI duplex receptacle and the120V
twist-lock receptacle, or a combination of both receptacles
as long as the total load does not exceed the generating
set capacity.

Figure 4D. 120/240V Full Power Switch

Simplified Diagram (Down Position)

Figure 4C. 120V Full Power Switch

Simplified Diagram (Up Position)

Figure 4B. Generator Components

GDP-5H — CONTROLS AND INDICATORS

When the

full power switch is in the

120V position, the 240V twist-lock
receptacle

cannot be used.