Db37 connector, Db37 connector -7, Connection cable and cable wiring – Moxa Technologies CP-114 Series User Manual

Page 47

Advertising
background image

Connection Cable and Cable Wiring

Industio CP-114 User's Manual

5-7

DB37 Connector

The following lists the pin assignments of the Industio CP-114 Series DB37 connector on the
bracket. With this information, you may fabricate any type of fan-out cables, such as DB37 to DB9
x 4 or DB37 to DB25 x 4.

For RS-232 Mode

Pin no.

Signal

Pin no.

Signal

29 RI2

19 TxD1

11 DCD2

30 DTR2

12 GND

31 DSR2

13 CTS2

32 RTS2

14 RxD2

33 TxD2

15 RI1

34 DCD1

16 DTR1

17 DSR1

36 CTS1

18 RTS1

37 RxD1

Note: Make shield grounded to connector.


For RS-422 Mode

Pin no.

Signal

Pin no.

Signal

1

20 CTS2-(A)

2 TxD2-(A)

21 RxD2-(A)

3 GND/VEE2 22 RTS2-(A)
4

CTS2+(B)

23 RTS2+(B)

5 TxD2+(B)

24 RxD2+(B)

6 CTS3-(A)

25 TxD3-(A)

7 RxD3-(A)

26 GND/VEE3

8 RTS3-(A) 27 CTS3+(B)
9 RTS3+(B)

28 TxD3+(B)

10 RxD3+(B)

29 CTS1-(A)

11 TxD1-(A) 30 RxD1-(A)
12 GND/VEE1 31 RTS1-(A)
13 CTS1+(B)

32 RTS1+(B)

14 TxD1+(B)

33 RxD1+(B)

15 CTS0-(A) 34 TxD0-(A)
16 RxD0-(A)

35 GND/VEE0

17 RTS0-(A)

36 CTS0+(B)

18 RTS0+(B)

37 TxD0+(B)

19 RxD0+(B)



Note:
Make shield grounded to connector.

For RS-485 Mode

Pin no.

Signal

Pin no.

Signal


2 Data2-(A) 25

Data3-(A)

3 GND/VEE2 26 GND/VEE3
5 Data2+(B) 28 Data3+(B)
11 Data1-(A) 34 Data0-(A)
12 GND/VEE1 35 GND/VEE0
14 Data1+(B)

37 Data0+(B)

Note: Make shield grounded to connector.