Master Bilt QMVM-72 User Manual

Qmvm series

Advertising
background image

ITEM NO. ______________________________________________________
PROJECT ______________________________________________________
LOCATION _____________________________________________________
DATE _________________________ QTY. ___________________________

908 Highway 15 North • New Albany, MS 38652
PHONE: 800-647-1284 or 662-534-9061 • FAX: 800-232-3966 or 662-534-6049 • www.master-bilt.com

CONSTRUCTION
• Standard electronic controller with

these features:

– Ability to monitor defrost functions

from the front panel interface

– Audible and visual alarm

– Eliminates room thermostat,
defrost termination/fan delay
control, defrost timer and digital
thermometer or other temperature
indicator

• 24 gauge painted textured galva-

nized steel exterior and interior

• Stainless steel floor pans (removable

for easy service)

• 2" foamed-in-place “zero ODP”

urethane insulation

• Shelves adjustable in 1" increments
• Three lighted tiers of two-position

shelving with price tag molding

• Perforated interior back wall and top

for better air flow

• Electric defrost
• Easily accessible electrical enclosure

REFRIGERATION
• Refrigerant: R-404A
• Front air intake and rear air discharge
• Self-contained, bottom mount

refrigeration system

• Minimum of 6" clearance between

cabinet back and wall and a clear-
ance of 10" at top

• Temp. range: 34° to 41°F (1° to 5°C)
• R-factor (insulation efficiency rating):

17.24

Drain plumbing hookup recom-
mended. Condensate pan available
if there is no access to drain plumb-
ing. Condensate pan must be field
installed and requires a dedicated
15 amp, 120 volt circuit.

FEATURES

QMVM SERIES

Quantum Series
Medium Temp
Vertical Open Display
Merchandisers

OPTIONS

Add suffix “R” for remote system

(QMVM-48E and -72E only)

Add suffix "ESS" for stainless steel

interior and exterior

Custom exterior colors

Condensate evaporator drain pan

NOTE: Must be field installed and

requires a dedicated 15A, 120v
circuit.

Condensate pump

Product hooks

Casters

Extra lighted shelves (one only)

Extra non-lighted shelves

1" vinyl bumper in choice of black,

blue, brown, green, red or white

Vinyl retractable night curtain

Locking metal night curtain (less

locks)

MODELS

QMVM-36E

QMVM-48E

QMVM-72E

QMVM-48E

Standard cord

and plug on

QMVM-36E and

QMVM-48E

models

Standard
white

Black also
available

NEW

STANDARD TEXTURED FINISH

WARRANTY
• Standard limited three year extend-

ed compressor and two year limited
parts and labor

Advertising
This manual is related to the following products: