Specifications, Local codes – Monessen Hearth BTU/Hr User Manual

Page 5

Advertising
background image

4

49D0090

49D0090

5

NATURAL GAS

NOTE: An external regulator is required to reduce supply pressure to a maximum of 10

1

/

2

" W.C. on

natural gas systems operating at higher pressure.

Thermostat Pressure

Regulator Pressure Setting: 4" w.c.
Gas Inlet Pressure: 10

1

/

2

" w.c.

Min. 5" w.c.

Gas Rate
Model Number Control Max BTU/Hr

Min BTU/Hr

DHHNT THERMOSTAT 30,000

15,000

PROPANE/LPG

Note: An external regulator is required to reduce supply pressure to a maximum of 13" W.C.

Thermostat Pressure

Regulator Pressure Setting: 10" w.c.
Gas Inlet Pressure: Max. 13" w.c.

Min. 11" w.c.

SPECIFICATIONS

AND

LOCAL CODES

LOCAL CODES

Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code, ANS Z223.1, also
known as NFPA 54. Available from:

American National Standards Institute, Inc.

National Fire Protection Association, Inc.

1430 Broadway

Batterymarch Park

New York, NY 10018

Quincy, MA 0226

Gas Rate
Model Number Control Max BTU/Hr

Min BTU/Hr

DHHPT THERMOSTAT 30,000