InSPECtIOn/SEtuP

COOlaNT (aNTiFReeze/SuMMeR COOlaNT)

perkins recommends antifreeze/summer coolant, for use in

their engines, which can be purchased in concentrate (and

mixed with 50% demineralized water) or pre-diluted. See the

perkins engine Owner’s Manual for further details.

The engine coolant capacity is 3.8 quarts (3.6 liters).

OpeRaTiON iN FReeziNg WeaTHeR

When operating in freezing weather, be certain the proper

amount of antifreeze (Table 10) has been added.

CleaNiNg THe RaDiaTOR

The engine may overheat if the radiator fins become

overloaded with dust or debris. Periodically clean the

radiator fins with compressed air. Cleaning inside the

machine is dangerous, so clean only with the engine turned

off and the

negative battery terminal disconnected.

aiR CleaNeR

Periodic cleaning/replacement is necessary. Inspect it in

accordance with the

perkins engine Owner’s Manual.

WaRNiNg

If adding coolant/antifreeze mix to the

radiator,

do not remove the radiator cap

until the unit has completely cooled. The

possibility of

hot coolant exists which can

cause severe burns.

Table 10. anti-Freeze Operating Temperatures

Vol %

Anti-

Freeze

Freezing Point

Boiling Point

°C

°F

°C

°F

50

-37

-34

108

226

NOTICE

When the antifreeze is mixed with water, the antifreeze

mixing ratio

must be less than 50%.

FaN BelT TeNSiON

A slack fan belt may contribute to overheating, or to

insufficient charging of the battery. Inspect the fan belt for

damage and wear and adjust it in accordance with the

perkins engine Owner’s Manual.
The fan belt tension is proper if the fan belt bends 10 to

15 mm (Figure 12) when depressed with the thumb as

shown below.

Figure 12. Fan Belt Tension

BaTTeRY

This unit is of negative ground.

DO NOT connect in reverse.

Always maintain battery fluid level between the specified

marks.

DO NOT over fill. Battery life will be shortened if

the fluid level is not properly maintained. Add only distilled

water when replenishment is necessary.
Check to see whether the battery cables are loose. Poor

contact may result in poor starting or malfunction.

always

keep the terminals firmly tightened. Coat the terminals with

an approved battery terminal treatment compound. Replace

battery with only recommended type battery.
The battery is sufficiently charged if the specific gravity

of the battery fluid is 1.28 (at 68° F). If the specific gravity

should fall to 1.245 or lower, the battery is dead and needs

to be recharged or replaced.
Before charging the battery with an external electric source,

be sure to disconnect the battery cables.

CauTiON

NeveR place hands near the belts or fan

while the generator is running.