F-5 1/07 © 2007 Imperial Commercial Cooking Equipment All specifications subject to change without notice. Printed in the U.S.A.

AIA

File #:

Specification #:

Imperial 75 lb. (41 L. )Fryers

Imperial Commercial Cooking Equipment

1128 Sherborn Street

Corona, CA 92879

800.343.7790

Ph: 951.281.1830

Fx: 951.281.1879

www.imperialrange.com

E-mail: [email protected]

Standard Exterior Finish Specifications
Front, sides, door, stub back and basket hanger shall be
constructed of stainless steel with welded and finished
stainless steel seams. Stainless steel legs shall be plate
mounted and include non-marking feet.

Frypot Specifications
All precision welded stainless steel vessel shall be
constructed of heavy 16 gauge stainless steel. Vessel shall
have a large foam area to prevent overflow. All vessel
edges shall be radius formed for added durability. Frying
area shall be 18" x 18" (457 x 457) with a 75 lbs. (41 L.)
oil capacity. There shall be five 14 gauge stainless steel,
fully immersed heat transfer tubes for maximum efficiency.
Heat retaining baffles and deflectors shall be inside of tubes
and easily removed for cleaning. Tube joints shall be weld-
ed on the outside of specially drawn fry vessels to prevent
leaks. Gas output shall be 175,000 BTU/hr (51 KW).
Snap acting thermostat shall have a 200

o

F - 400

o

F

(93

o

C - 204

o

C) temperature range. Fail-safe high limit

control shall shut off all gas if oil temperature exceeds
435

o

F. (224

o

C). Safety pilot shall be

100% shut off.

Large cool zone beneath tubes shall capture food and
breading particles and keep them out of the frying area to
improve food taste and prolong oil life. Fine mesh crumb
screen shall be removable. Unit shall include removable
drain pipe and clean out rod. Drain shall be a 1

1/4

" (32) full

port drain valve for quick draining.

Gas
Manifold pressure is 4" W.C. for natural gas or 11" for propane
gas. Manifold size

3/4

" NPT.

3/4

" pressure regulator supplied

with equipment to be installed at time of connection. Specify
type of gas and elevation if over 2,000 ft. (610 m).

Clearance
For use only on non-combustible floors. Legs or casters are
required for non-combustible floors; or 2" (51) overhang is
required when curb mounted. Provide 0" clearance from
non-combustible surfaces and 6" (152) from combustible
surfaces.

Optional Items

Rear gas pressure regulator

Portable oil filter unit

Fryer drain station with a storage cabinet

Quick disconnect hose and restraining device

Stainless steel strip to cover between fryers

Various size fry baskets

6" (152) swivel casters (front two casters are locking)

Stainless steel backguard

Optional Fryer/Filter Systems

Pre-packaged systems with matching cabinet and
built-in filter and pan

Stainless steel dump station and food warmer

System options include solid state thermostat control,
computer fry control and basket lifts

75 lb. (41 L.) Fryers

Oil Capacity

Gas Output

Ship Wt.

Model#

Description

Lbs.

(Liters)

BTU

(KW)

(Kg.) Lbs.

IFS-75

Stainless Steel Frypot

75

(41)

175,000

(51)

(122) 270

IFS-75SS

Range Match with Stainless Steel Frypot

75

(41)

175,000

(51)

(122) 270

All measurements in ( ) are metric equivalents.

Crated Dimensions: 36" (891) d x 19

1/2

" (495) w. Add 2" (51) to height of unit.