Physical Specifications

Size and Weight

Unpacked size and weight are as follows:

Width Depth Height Weight

----- ----- ------ ------

Base Printer 2106mm (69.8") 735mm (28.9") 1476mm (58.1") 302kg (664 lb)

Printer+HCF 2314mm (91.1") 735mm (28.9") 1476mm (58.1") 381kg (838 lb)

Note: " denotes inches.

Operating Environment

Infoprint 2085:

Operating Temperature: 50 to 90 deg F (10 to 32 deg C)

Humidity: 15 to 85% RH; 26 deg C max wet bulb

Altitude: 8,200 ft (2500 m)

Electrical Specifications

North America - 208 Volt, 60 Hz

Europe - 220-240 Volt, 50/60 Hz

Japan - 200 Volt, 50/60 Hz

Power Consumption

Less than 3,000 Watts.

Acoustics

Mode Infoprint 85 Infoprint 105 Remark

----------------- ------------ ------------- --------------

Operating 78 dB(A) 80 dB (A) Sound Power

Idle 63 dB(A) 69 dB (A) Sound Power

Operator position 72 dB(A) 74 dB (A) Sound Pressure

User Position 72 dB(A) 74 dB (A) Sound Pressure

Ozone Emissions

Infoprint 2085 and 2105 ozone emissions are less than 0.02 mg/hr in the continuous copying mode.

Limitations

Not applicable.

http://gsmserv.boulder.ibm.com/cd/usmhw/M2785$01.htm (36 of 47)5/25/2005 7:01:07 AM