Cornelius Door Latch User Manual

Installation instructions, Parts list tools required

Advertising
background image

Door Latch Assembly Installation Instructions

© 2004, IMI Cornelius Inc.

- 1 -

Publication Number: 729011146INS

INSTALLATION INSTRUCTIONS

R

EMOVAL

AND

I

NSTALLATION

OF

D

OOR

L

ATCH

A

SSEMBLY

Q

UEST

NOTE: Removing the existing door catch/switch with the replacement catch will remove the auto-
matic sold out reset function of the machine. This feature can still be used or totally defeated
depending on users preference.

OPTION 1:

By removing the existing switch and not jumping the board the sold out will work, but not

reset unless the pump door switch is manually reset after each refill. If the switch is not manually reset
the light will not go out even after installing new product.

OPTION 2:

To disable the sold out feature jumpers are added to the control board in the sold out plug

location. The sold out will now be disabled and never come on.

Installation of these options are described below.

Parts List

Tools Required

• Hex Screw Driver

• Electrical Tape

Description

Part Number

Qty

Bracket

720201471

1

Sold Out Jumper Board

11749

4

Jumper Switch

720302204

1

Spacer

720705306

1

Screw Plastic #8 x ¾”

07015001

2

Screw 6-32 x 3/8”

0700203

2

Washer .145x.5x .03

07301043

2

Screw 6-32 x 1/4

0700201

2

Latch

720532112

1

Catch

720202415

1

FIGURE 1

Revision Date: June 30, 2004