John Deere AC-375LP User Manual

Page 18

Advertising
background image

Service

18

Operator’s Manual

CLEANING FAN (CONT.):
14. Dry fan thoroughly.
15. Replace fan on motor shaft. Make sure setscrew is

touching back of flat surface on motor shaft (Fig. 7).

16. Place setscrew on flat of shaft. Tighten setscrew firmly

(40-50 inch-pounds).

17. Remove two nuts and bolts securing motor mount to

shell.

18. Pull motor and fan from shell. Turn motor and fan

around. Carefully place back in shell. Note: Fan will

go into shell first.

19. Line up mounting holes in shell with holes on motor

mount. Replace four bolts through shell and motor

mount. Insert bolts from outside of heater. Tighten nuts

firmly.

20. Route motor wires through hole in bottom of shell

(Fig. 4).

21. Connect motor wires as follows (Fig. 3):
• white wire—to terminal board
Note: Attach to empty connector on white wire side of

terminal board.

• black wire—to terminal board
Note: Attach to empty connector on black wire side of

terminal board.

• blue wire—to thermal switch wire
• orange wire—to solenoid valve
• green wire—to grounding screw on shell
22. Replace side cover.
23. Replace fan guard.

(Fig. 7)

Fan

Hub

Setscrew

Motor

Shaft

Advertising