JVC 340 SC User Manual

Page 70

Advertising
background image

Chapter 2—Functional Descriptions

2-58

Model 330. 340SC, and 370SC Service Manual

Table 2-11

Video Amplifier Board I/O Signals

Video Processor Board

Input

Description

VIN

COAX input from VPB via the backplane. Video signal of 1V peak-

to-peak maximum.

/ENABLE

TTL level DC signal which controls grid voltages. High causes G2

to be pulled to +15V and G1 to be pulled to -200V shutting off
the CRT beam.

CLAMP

TTL level pulse controlling DC restore. Restores black level of

cathode voltage to +84V.

BLANKING

TTL level signal controlling video blanking. Pulls G1 to 30V below

normal voltage to turn off beam.

Outputs

Description

BEAM

Positive voltage indicating beam current averaged over several lines.

1mV = 1uA of beam current.

/VIDOK

Indicates health of the +100V cathode supply. Open collector output

opens when supply goes below 64V.

CRTs

Output

Description

FOCUS

Focus voltage directly from HVPS to CRT.

GRID1

Regulated DC voltage to Grid1. Nominally -81V during normal

operation. During blanking, G1 is -111V, and during /ENABLE
high, G1 is -200V.

GRID2

Variable DC voltage to Grid2. G2 voltage is normally 800 to

1200V. When /ENABLE high, G2 is 15V.

CATHODE

DC black level modulated by video signal. DC black level is +84V.

Modulation is negative-going 75V peak-to-peak max.

FILAMENT

6.3V filtered goes to filament.

FILAMENT

RTN

Return from filament supply.

High Voltage Power Supply

Inputs

Description

-200V

Power supply to Grid1 regulator.

FOCUS

Pass-through from HVPS to CRT.

G2

+100V to +1400V supply to Grid2. Passes through G2 pulldown

circuit for protection.