Connecting an external control unit

When connecting the external control unit to the MAKE terminal, you can operate the following functions through the
MAKE terminal;
• Turn on or off the Monitor.

Preparation: The POWER switch on the rear must be set to “| (on)” (so that the Monitor is in standby mode).

• Select the input.

Preparation: “REMOTE SWITCH” should be set correctly to select your desired input (see page 27).

Notes:
• There is no remote control on/off switch. When a plug is inserted to the MAKE terminal, remote control through the

external control unit is automatically activated.

• When the other REMOTE terminals are used at the same time, transmitted commands through the MAKE terminal have

priority over those through the other terminals.

IMPORTANT:
External control unit is not commercially available in the market. When you need it, consult your dealer.

• MAKE terminal

• External control unit

Pin number

Signal name

1

GND

2

GND

3

SW2

4

SW1

5

SW DET

6

GND

Signals

transmitted

=

=

=

TTL level

H: Power Off

L: Power On

H: Input A*

L: Input B*

H: Not connected

L: Connected

* Input A and Input B will be determined by the “REMOTE

SWITCH” setting.