5

Do not face the battery when making the final connection.

7.5

When disconnecting the charger, always do so in the reverse order of the

7.6

connecting procedure and break the first connection while as far away

from the battery as practical.
A marine (boat) battery must be removed and charged on shore. To

7.7

charge it onboard requires equipment specially designed for marine use.

BATTERy CHARGING - AC CONNECTIONS

8.

This battery charger is for use on a nominal 120-volt circuit.

8.1

DANGER – Never alter AC cord or plug provided – if it does not fit the

outlet, have proper outlet installed by a qualified electrician. Improper

connection can result in a risk of an electric shock.
Recommended minimum AWG size for extension cords for battery

8.2

chargers:

25

50

100

150

(7.6)

(15.2)

(30.5)

(45.6)

0

2

18

18

18

16

2

3

18

18

16

14

3

4

18

18

16

14

4

5

18

18

14

12

5

6

18

16

14

12

6

8

18

16

12

10

8

10

18

14

12

10

10

12

16

14

10

8

12

14

16

12

10

8

14

16

16

12

10

8

16

18

14

12

8

8

18

20

14

12

8

6

a

If the input rating of a charger is given in watts rather than in

amperes, the corresponding ampere rating is to be determined

by dividing the wattage rating by the voltage rating ± for

example:

1250 watts/125 volts = 10 amperes

Length of cord, feet (m)

AWG size of cord

AC input rating,

amperes