20 plug (as recommended), Disconnect switch (as recommended), Spindle rotation and power conn- tection – Southbend 16" x 60" Lathe 440V w/ Dro sb1015f User Manual

Page 105

Advertising
background image

For Machines Mfg. Since 8/09

EVS Toolroom Lathes

-11-

E L E C T R I C A L

Spindle Rotation Switch

220V Power Connection

440V Power Connection

Fig. 10. Spindle rotation switch location.

NC

COM

NC

COM

NO

NO

7

8

6

9

Spindle Rotation Switch,

Figure 10.

spindle rotation
and power conn-
tection

Ground

Hot

Hot

Hot

15-20 PLUG

(as recommended)

L3

L2

L1

1

2

3

5

6

4

MASTER

POWER SWITCH

L3

L3

L2

L2

L1

L1

Ground

Hot

Hot

Hot

DISCONNECT

SWITCH

(as recommended)

L3

L2

L1

MASTER

POWER SWITCH

L3

L3

L2

L2

L1

L1

1

2

3

5

6

4

Inside Electrical
Box, Page 7.

Inside Electrical
Box, Page 7.

6

6

7

9

7

Spindle Rotation

Switch

To Main Junction
Block, Page 7.

6