PROBLEM
POSSIBLE CAUSE
REMEDY
No power
No sound
Distorted or abnormal
sound
Vibrating sound
Too noisy
No recording
• The AC input cord is disconnected.
• The POWER(ON/STANDBY) button is
not pressed completely.
• Unrecorded tape is loaded.
• Incorrect connections.
• Incorrect operation of the receiver.
• Dirty head.
• Incorrect selection of the Dolby B NR
system.
• The tape is stretched or wrinkled.
• Dirty capstans or pinch rollers.
• The tape is irregularly wound.
• Magnetized head.
• Poor connections.
• The tabs have been removed.
• Dirty head.
• Too low recording level.
• Connect the cord securely.
• Press the POWER(ON/STANDBY)
button to ON.
• Load the recorded tape.
• Make connections correctly.
• Operate the receiver correctly.
• Clean the head.
• Select the Dolby B NR mode or the
Dolby B NR OFF mode.
• Replace the tape.
• Clean the capstans or pinch rollers.
• Wind the tape by advancing or
rewinding rapidly.
• Demagnetize the head.
• Check the connections and connect
all cords securely.
• Cover with the adhesive tape.
• Clean the head.
• Adjust the recording level properly.