Special remarks – Sanyo CH3682 User Manual

Page 72

Advertising
background image

12

A. In Heating Mode: (

)

B. In Cooling Mode: (

)

• Unoccupied Mode triggers Heating or Cooling Operation in

response to the room temperature, but when this happens, the
remote control unit will continue to display the Operation mode set
by the user.

• If the room temperature rapidly changes, the room temperature

may get over the upper or lower limit when the unoccupied function
is activated.

• The remote control unit should be used in the location specified in

“REMOTE CONTROL UNIT INSTALLATION POSITION” on
page 8.

• The air conditioner’s stop order (stated in (2) / above) is valid only

when the unoccupied function is operated.

SPECIAL REMARKS

How it works?

• Once the room temperature reaches the level that was set, the

unit’s operation frequency is changed automatically.

• During DRY operation, the fan speed automatically runs at lower

speed for providing a comfortable breeze.

• ‘‘DRY’’ operation is not possible if the indoor temperature is 59 °F

or less.

Heating performance

• When High power operation

, Fan speed Automatic operation

, HIGH

or MEDIUM

has been changed to Fan speed

LOW

, Quiet operation

or Night Setback

, the fan

speed may not be reduced to the desired setting immediately but
rather it may be reduced slowly in steps due to the operating status
of the air conditioner. (A maximum of 5 minutes are required for the
change to be completed.)

• Because this air conditioner heats a room by drawing in the heat of

the outside air (heat pump system), the heating efficiency will fall
off when the outdoor temperature is very low. If sufficient heat
cannot be obtained with this air conditioner, use another heating
appliance together with it.

Defrosting

• When the outdoor temperature is low, frost or ice may form on the

heat exchanger coil, reducing heating performance. When this
happens, a microcomputer defrosting system operates. At the
same time, the fan on the indoor unit stops and the OPERATION
lamp lights red and orange alternately until defrosting is completed.
Heating operation restarts after several minutes. (This interval will
vary slightly depending upon the outdoor temperature and the way
in which frost forms.)

Cold draft prevention

• For several minutes after the start of heating operation, the indoor

fan runs at a lower speed until the indoor heat exchanger coil has
warmed up sufficiently. However, the fan may remain stopped when
the room temperature is low. This is because the COLD DRAFT
PREVENTION SYSTEM is in operation.

• Sometimes the indoor unit may not get to the set fan speed such as

LOW under cool operation at very low outdoor temperatures due to
the indoor unit being protected from ice or frost.

• In the event of power failure, the unit will stop. When the power is

resumed, the unit will restart automatically in approximately
5 minutes by the remote control unit.
If the remote control unit is on and left in a location where the unit
can receive a signal, then the unit will automatically restart in
approximately 5 minutes of power being restored.

Clicking sound is heard from the air conditioner

• In heating or cooling operation, any plastic parts may expand or

shrink due to a sudden temperature change. In this event, a
clicking sound may occur. This is normal, and the sound will soon
disappear.

• The remote control unit sends the setting condition to the air

conditioner regularly at five minute intervals.

(1)

53
50
46

(2)

(1) When the room temperature drops below 46°F, Heating

Operation will begin.

(2) When the room temperature rises to above 53°F, Heating

Operation will stop.

The above actions will repeat so that the room temperature is
maintained at about 50°F.

Room
Temperature (°F)

Heating
starts

Time

Heating
stops

(1)

89
86
82

(2)

Room
Temperature (°F)

Cooling
starts

Time

Cooling
stops

(1) When the room temperature rises above 89°F, Cooling

Operation will begin.

(2) When the room temperature drops below 82°F, Cooling

Operation will stop.

The above actions will repeat so that the room temperature is
maintained at about 86°F.

NOTE

‘‘DRY’’ (

) Operation

Heating (

) Operation

Cooling ( ) operation

Power failure during operation

Clicking Sound

Remote Control Unit

OI-149-12-EG