R3000x remote control, 18 r3000x remote control – Simrad AUTOPILOT SYSTEM AP50 User Manual

Page 66

Advertising
background image

Simrad AP50 Autopilot

64

20221032B

Rudder drive interface:

Danfoss PVEM:................... Nominal U

DC

=12/24V, I=0.25/0.5mA, neutral 0.5*Un,

control range 0.25*U

DC

to 0.75*U

DC

,

valve saturated for<0.25*U

DC

or >0.75*U

DC

.

Analog control, internal supply: ...Control range±10V, max. 5 mA, galvanic isolated
Analog control, external supply: ............... U

DC

12-24VDC, control range 0- U

DC

or

±U

DC

/2, max. 5 mA

ON/Off valve:...............................Port/stbd on/off, open collector, galvanic isolated,

external common plus or minus, 3A max.

Rudder enable output: .............. Open collector, external or internal +, max 500 mA.

The internal +12V output is limited to 100mA

and may be used for an external relay operated by Hi/Lo output

to switch rudder control signal between autopilot

and external manual control.

3.18 R3000X Remote Control

pfjo^a=oPMMMu

STBY AUTO

Dimensions:.................................See Figure 3-14
Weight: .........................................0.4 kg (0.9 lbs.)
Material: .........................Epoxy-coated aluminum
Environmental Protection...............................IP56
Safe distance to compass:.............. 0.15 m (0.5 ft.)
Temperature range:
Operating: ...........–25 to +55°C (–13 to +130°F)
Storage:...............–30 to +80°C (–22 to +176°F)
Cable:....................................7 m (23 ft.), shielded
Mounting bracket: ................................... Supplied

Figure 3-14 R3000X Remote Dimensions