Schumacher Power Converter X141B User Manual

Page 9

Advertising
background image

• 9 •

4. The case temperature becomes hot (exceeds 145°F). The

Green and Red LEDs are on, with a buzzer. Solution: Allow

the converter to cool. Do not block the cooling slots or air

flow over and through the converter. Reduce the load on the

converter to the continuous rated output.

RESET: To reset after shutdown occurs:

1. Disconnect the converter from the 12V power source.

2. Check the source of the problem and correct.

3. Reconnect the converter to the 12V power source.

NOTE: If the red LED is lit and the green LED is not, see the

Troubleshooting section.

8. IF THE CONVERTER FUSE BLOWS

Your power converter is fitted with a fuse, which should not have

to be replaced under normal operating conditions. A blown fuse

is usually caused by reverse polarity or a short circuit within the

device or equipment being operated.

If the fuse does blow:

1. Disconnect the device or equipment immediately.

2. Find the source of the problem and repair it.

3. Install a new fuse (25A). The fuse can be found on the back of

the converter.

Do not install a fuse with a higher amp rating than

the original fuse, as this may damage the converter and any

product you use with the converter. Make sure to correct the

cause of the blown fuse before using the converter again.

Advertising