Figure 13. Valve VR8204 or VR8304

Figure 14.

2.

Intermittent Pilot System (IID).
FOR BOILERS EQUIPPED WITH HONEYWELL GAS
VALVE VR8204 OR VR8304 (see figures 13 and 14).

SAFETY INFORMATION

FOR YOUR SAFETY READ BEFORE OPERATING

WARNING: If you do not follow these instructions exactly,
a fire or explosion may result causing property damage,

personal injury or loss of life.

A. This appliance is equipped with an ignition device which

automatically lights the pilot. DO NOT try to light the pilot

by hand.

B. BEFORE OPERATING smell all around the appliance area

for gas. Be sure to smell next to the floor because some

gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

DO NOT try to light any appliance.

DO NOT touch any electric switch; DO NOT use any

phone in your building.

Immediately call your gas supplier from a neighbor's

phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire

department.

C. Use only your hand to push in or turn the gas control knob.

NEVER use tools. If the knob will not push in or turn by

hand, DON'T try to repair it, call a qualified service techni-

cian. Force or attempted repair may result in a fire or

explosion.

D. DO NOT use this appliance if any part has been underwa-

ter. Immediately call a qualified service technician to

inspect the appliance and to replace any part of the control

system and any gas control which has been underwater.

Operating Instructions

1. STOP! Read the safety information above.
2. Set the thermostat to lowest setting.

3. Turn off all electric power to the appliance.

4. This appliance is equipped with an ignition device which

automatically lights the pilot. DO NOT try to light the pilot

by hand.

5. Remove control access panel.

6. Turn gas control knob clockwise till knob stops then

continue to "OFF". DO NOT force.

7. Wait five (5) minutes (longer for propane) to clear out any

gas, then smell for gas, including near the floor. If you then

smell gas, STOP!

Follow "B" in the safety information

above on this page. If you don't smell gas, go to next step.

8. Turn gas control knob counterclockwise to "ON".

9. Replace control access panel.

10. Turn on all electric power to the appliance.

11. Set thermostat to desired setting.

12. If the appliance will not operate, follow the instructions "To

Turn Off Gas To Appliance" and call your service techni-

cian or gas supplier.

To Turn Off Gas To Appliance

1. Set the thermostat to lowest setting.

2. Turn off all electric power to the appliance if service is to

be performed.

3. Remove control access panel.

4. Turn gas control knob clockwise till knob stops,

then continue to "OFF". DO NOT force.

5. Replace control access panel.

III. BURNER ADJUSTMENT
A. Adjust gas input rate:

1. Consult gas supplier for higher* heating value of gas.

(Btu/cu.ft.)

2. Set thermostat high enough so that boiler will remain on

while checking rate.

3. Measure manifold pressure at 1/8" tapping. Correct man-

ifold pressure for gas used is printed on boiler rating

plate. NOTE: Gas pressure may be adjusted by turning

pressure regulator screw on combination gas valve (turn

clockwise to increase pressure, counterclockwise to

decrease pressure).

a. Input for PROPANE is approximately at rating shown

on rating plate when manifold pressure is 9-1/2" water

column.

b. Input for NATURAL GAS is approximately at rating

when manifold pressure is 3-1/2" water column, but

should be checked on the gas meter:

Btuh Input = Btu/cu. ft. x cu. ft. metered

in 3 minutes x 20

Example #1:

For 1000 Btu/cu.ft. gas, this becomes:

Btuh Input = cu. ft. metered in 3 minutes

x 1000 Btu/cu.ft. x 20

Example #2:

For 1050 Btu/cu.ft. gas, this becomes:

Btuh Input = cu. ft. metered in 3 minutes

x 1050 Btu/cu.ft. x 20

4. The higher* heating value of gas varies substantially for

different localities. Consult with Slant/Fin’s Technical

Service Dept. for re-orificing procedures if any of the fol-

lowing apply:

10