Skylink GARAGE DOOR OPENER UNIVERSAL RECEIVER Model UR-100 User Manual

Skylink Kitchen

Advertising
background image

1. Disconnect the power from

your existing garage door
opener to avoid triggering
the door accidentally dur-
ing installation.

2. Open your existing wall

mounted garage door
opener button.

3. Connect the wires to the

terminals and tighten as
shown. If your opener has
more than two terminals,
attach the wire to the same
two terminals that the wire

The Universal receiver works with Skylink remote transmitters
model #66, #66C, #36, #36C, #68, #68C, #68B, #68G, #68R,
#88, #88C, #88P. Use a paper clip to set the receiver DIP
switches to match your Skylink transmitter. Each switch of the
receiver has 2 positions (“ON” or “OFF”).

WARNING: Unplug the
receiver before chang-
ing code setting.

PROGRAMMING THE RECEIVER

DIP
SWITCHES

5. The code connector (see dia-

gram J) has 12 rows of posts,
each rows has 3 posts. Each

PROGRAMMING THE SKYLINK MODEL #66, 66C

1. Locate frequency switch

on the top of the trans-
mitter and set to position
A. (See diagram A)

2. To program the model

#66, #66C, open the
case with a coin. (See
diagram B)

Diagram A

Diagram B

3. Use a pen or paper clip

to set the corresponding
DIP switches numbered
1 through 9 so that the
switches on the trans-
mitter match those on
the receiver. Each switch
of the transmitter has 3
positions (“ + ”, “ 0 ”,
“ - ”). To operate with
Skylink #UR-100, only
set the switches to “ + ”
or “ 0 ”. Do not use “ - ”
position. Leave the re-
maining DIP switches in

DIP Switch Location

1. Locate frequency switch

on the top of the trans-
mitter to position A.
(See diagram D)

2. To program the model

#36, #36C, open the
case with a coin. (See
diagram E)

Diagram D

Diagram E

INSTALLATION

DO NOT REMOVE ANY
WIRES.

Replace button casing.

4. Plug in the wires to the

receiver as shown. Then,
plug in the receiver to an
electrical outlet.

5. Re-connect the power to

your garage door operator.

6. Press the wall button to

test and check wiring for

RECEIVER

Existing wall
mounted button

ANTENNA

from the garage door
opener is connected to.

PROGRAMMING THE SKYLINK MODEL #36, 36C

4. Test the transmitter with

the Universal receiver.

DIP Switch Location

4. Test the transmitter with

the Universal receiver.

proper operation.

Diagram C

Diagram F

UNIVERSAL RECEIVER #UR100

SKYLINK TRANSMITTER

DIP SWITCH POSITION SETTING

DIP SWITCH POSITION SETTING

1

ON / OFF

1

+ OR 0

2

ON / OFF

2

+ OR 0

3

ON / OFF

3

+ OR 0

4

ON / OFF

4

+ OR 0

5

ON / OFF

5

+ OR 0

6

ON / OFF

6

+ OR 0

7

ON / OFF

7

+ OR 0

8

ON / OFF

8

+ OR 0

9

ON / OFF

9

+ OR 0

DIP switch setting to match with Skylink Universal Receiver and Skylink Transmitter

Refer to the chart below. If any of the DIP switches in the Universal Receiver
are set to “ON” position, set the switches in the Skylink transmitter to the “+”
position. If DIP switches on the Universal Receiver are set to “OFF” position,
set the switches in the Skylink transmitter to the “0” or central or blank position.

the transmitter at “0” or
the center position. (See
diagram C)

3. Use a pen or paper clip

to set the corresponding
DIP switches numbered
1 through 9 so that the
switches on the trans-
mitter match those on
the receiver. Each switch
of the transmitter has 3
positions (“ + ”, “ 0 ”,
“ - ”). To operate with
Skylink #UR-100, only
set the switches to “ + ”
or “ 0 ”. Do not use “ - ”
position. Leave the re-
maining DIP switches in

the transmitter at “0” or
the center position. (See
diagram F)

1. Locate frequency switch

on the top of the trans-
mitter and set to position
A. (See diagram G)

Diagram G

Diagram H

2. To program the model

#38, #38C, open the
case with a coin. (See
diagram H)

3. The transmitter contains 8

brand jumpers (see dia-
gram I) and 12 code con-
nectors. (See diagram J).

Code connector Location

1 2 3 4 5 6 7 8

Brand Jumper

4. The brand jumper has 8 rows

of posts, each row has 2 posts.
(see diagram I). The connec-
tor, (see diagram K), must be
placed to the position ‘ 7 ’.

Diagram I

Diagram K

Diagram J

To operate with Skylink #UR100,
only set to “ + ”or “ 0 ” position.
Do not place the connector to
the middle & bottom posts “ - ”
position.

When removing a connector to
set a row to the neutral position,
save the connector in case you
change the code at a later date.

row contains one connec-
tor (see diagram K) for a
total of 12 connectors.

PROGRAMMING THE SKYLINK MODEL #38, #38C

If the connector is placed on the top and middle posts, that
row is set on “ + ” or “ON”. If the connector is removed com-
pletely, (not placed on any posts), it is set to “ 0 ” or the neu-
tral position. (see diagram L for examples of how to set a row
to the three different positions).

+

’ OR ‘ON’

‘0’ = BLANK

Diagram L

Advertising